Ilite Tile Diagnostic - Barco ILite 6 Service Manual

Hide thumbs Also See for ILite 6:
Table of Contents

Advertisement

3. Diagnostic
3.1

ILite tile diagnostic

Status LED's re-sync unit
The re-sync unit of the ILite tile is provided with three status LED's. One green and two red LED's. The LED's are horizontally
mounted with the green LED in the middle. The green LED lights up indicating the SMPS has started and the re-sync unit is operating
normally. The red LED's indicate the status of the sync pulses and the incoming data signal.
Image 3-1
A
Left red LED.
B
Green LED.
C
Right red LED.
Left red LED
Green LED
Flashing
OFF
Flashing
ON
OFF
OFF
OFF
ON
OFF
10
Right red
Diagnostic
LED
ON
OFF
ILite tile receives start-up signal on the left I/O port but no sync is present on the
data signal.
ON
Flashing
ILite tile receives start-up signal on the right I/O port but no sync is present
on the data signal.
ON
Flashing
ILite tile receives no start-up signal and no sync is present.
ON
OFF
ILite tile is functioning normal, data signal and sync are received on the left
I/O port.
ON
ON
ILite tile is functioning normal, data signal and sync are received on the right
I/O port.
ON
OFF
The power unit of the ILite tile is started but the re-sync unit is malfunctioning.
OFF
OFF
The power unit of the ILite tile is not started or the resync-unit is malfunctioning.
OFF
OFF
Re-sync unit receives data from the left but no power.
OFF
ON
Re-sync unit receives data from the right but no power.