ELECTRO FREEZE CS700-FG Operator's Manual page 42

Compact series shake freezer
Table of Contents

Advertisement

ELECTRO FREEZE Shake Model CS700-FG
13
Troubleshooting Charts
PROBLEM
PROBABLY CAUSE
1. Freezer unplugged.
2.
3. Actuator (plunger) rod not installed
Unit does not
operate.
4. Off on high pressure cut-out control.
5. Circuit breaker tripped.
6. Faulty selector switch
7.
Mix or water
leaking from
1.
drain tube to
drip tray.
1. Faulty o-ring.
Mix leaking
at dispensing
2.
head.
1.
Dispensed
product too
2. Torque control not set firm enough.
soft. (Product
temperature
3. Component failure.
above 28°F
[-2.2°C])
4.
32
Fuse blown or breaker tripped at main
disconnect.
Disconnected or broken wire in electrical
circuit.
Damaged beater shaft seal or installed
improperly.
Head not properly installed.
Dirty or blocked condenser, restricted air
flow.
Leak in refrigeration system resulting in
little or no refrigeration.
— continued
REMEDY
1. Plug in freezer.
Make sure your freezer is connected
to a separate circuit independent from
any other electrical equipment. Have
2.
technician check fuse or breaker
size and check for low voltage; if not
within 10% of nameplate rating call
power company.
3. Install actuator (plunger) rod.
Water turned off or defective water
4.
regulating valve. Check water supply.
Contact your Electro Freeze
5.
distributor for service.
Contact your Electro Freeze
6.
distributor for service.
Contact your Electro Freeze
7.
distributor for service.
Replace cup seals on washer. Install
1.
properly.
1. Replace o-ring.
Install head properly. Replace o-ring
2.
if pinched.
Unblock condenser or have cleaned
1.
by your Electro Freeze distributor.
Contact your Electro Freeze
2.
distributor for service.
Contact your Electro Freeze
3.
distributor for service.
Contact your Electro Freeze
4.
distributor for service.
185231-17