6. TROUBLESHOOTING

6. TROUBLESHOOTING
If an alarm has occurred, refer to this chapter and remove its cause.

6.1 Alarms and warning list

When a fault occurs during operation, the corresponding alarm or warning is displayed. Refer to section 6.2 of
this manual and section 8.2 of the MR-J3- B Servo Amplifier Instruction Manual at an alarm occurrence and
section 6.3 of this manual and section 8.3 of the MR-J3- B Servo Amplifier Instruction Manual at a warning
occurrence, and then take the appropriate action. When an alarm occurs, the ALM turns OFF.
After its cause has been removed, the alarm can be deactivated in any of the methods marked
deactivation column. The alarm is automatically canceled after removing the cause of occurrence.
Display
10
Undervoltage
12
Memory error 1(RAM)
13
Clock error
15
Memory error 2(EEP-ROM)
16
Encoder error 1 (At power on)
17
Board error
19
Memory error 3(Flash-ROM)
1A
Motor combination error
20
Encoder error 2
24
Main circuit error
28
Linear encoder error 2
2A
Linear encoder error 1
30
Regenerative error
31
Overspeed
32
Overcurrent
33
Overvoltage
34
Receive error 1
35
Command frequency alarm
36
Receive error 2
37
Parameter error
Fully closed loop control error
42
detection
45
Main circuit device overheat
46
Servo motor onerheat
47
Cooling fan alarm
50
Overload 1
51
Overload 2
52
Error excessive
70
Load side encoder error 1
71
Load side encoder error 2
8A
USB communication time-out
8E
USB communication error
888
Watchdog
Note 1. Deactivate the alarm about 30 minutes of cooling time after removing the cause of occurrence.
2. In some controller communication status, the alarm factor may not be removed.
3. Set parameter No.PE03 to "1
POINT
Alarms and warnings are basically the same as those of MR-J3- B servo
amplifier. This chapter describes the contents different from those of MR-J3-
B servo amplifier.
As soon as an alarm occurs, make the servo off status and interrupt the main
circuit power.
Remedies for warnings are the same as those of MR-J3- B servo amplifier.
Refer to chapter 8 of the MR-J3- B Servo Amplifier Instruction Manual.
Name
Power
OFF ON
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
" to deactivate.
Alarm deactivation
Error reset CPU reset
(Note 1)
(Note1 )
(Note 2)
(Note 3)
(Note 3)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
6 - 1
Display
Name
96
Home position setting error
E0
Excessive regeneration warning
E1
Overload warning 1
E4
Parameter warning
E6
Servo forced stop warning
E7
Controller emergency stop warning
E8
Cooling fan speed reduction warning
E9
Main circuit off warning
EC
Overload warning 2
ED
Output watt excess warning
in the alarm