compressor is regularly operating in ambient temperatures above 35 °C (95 °F), oil lifetime is reduced
significantly. In such case it is recommended to use Roto-Xtend Duty Fluid.
6.3

Storage after installation

Procedure
Run the compressor regularly, e.g. twice a week, until warm. Load and unload the compressor a few times.
6.4

Service kits

Service kits
For overhauling and for preventive maintenance, a wide range of service kits is available. Service kits
comprise all parts required for servicing the component and offer the benefits of genuine Atlas Copco parts
while keeping the maintenance budget low.
Also a full range of extensively tested lubricants, suitable for your specific needs is available to keep the
compressor in excellent condition.
Consult the Spare Parts List for part numbers.
6.5

Disposal of used material

Used filters or any other used material (e.g. desiccant, lubricants, cleaning rags, machine parts, etc.) must
be disposed of in an environmentally friendly and safe manner, and in line with the local recommendations
and environmental legislation.
Electronic components are subject to the EU Directive 2012/19/EC for Waste Electrical and Electronic
Equipment (WEEE). As such, these parts must not be disposed of at a municipal waste collection point.
Refer to local regulations for directions on how to dispose of this product in an environmental friendly
manner.
84
If the compressor is going to be stored without running from time to time, protective
measures must be taken. Consult your supplier.