Taking Out Of Operation - Atlas Copco GA 15 Instruction Book

Hide thumbs Also See for GA 15:
Table of Contents

Advertisement

5.7

Taking out of operation

Warning
Procedure
Step
Action
-
Stop the compressor and close the air outlet valve.
-
Open the manual condensate drain (if provided). Consult section
the drain valve.
-
-
Switch off the voltage and disconnect the compressor from the mains.
-
Unscrew the oil filler plug only one turn to permit any pressure in the system to escape.
-
Shut off and depressurise the part of the air net which is connected to the outlet valve.
Disconnect the compressor air outlet pipe from the air net.
-
Drain the oil.
-
Drain the condensate circuit and disconnect the condensate piping from the condensate net.
80
The operator must apply all relevant
Safety
precautions.
Condensate system
Instruction book
to locate
API459842