5.7
Taking out of operation
Warning
Procedure
Step
Action
-
Stop the compressor and close the air outlet valve.
-
Open the manual condensate drain (if provided). Consult section
the drain valve.
-
-
Switch off the voltage and disconnect the compressor from the mains.
-
Unscrew the oil filler plug only one turn to permit any pressure in the system to escape.
-
Shut off and depressurise the part of the air net which is connected to the outlet valve.
Disconnect the compressor air outlet pipe from the air net.
-
Drain the oil.
-
Drain the condensate circuit and disconnect the condensate piping from the condensate net.
80
The operator must apply all relevant
Safety
precautions.
Condensate system
Instruction book
to locate