Stopping - Atlas Copco GA 15 Instruction Book

Hide thumbs Also See for GA 15:
Table of Contents

Advertisement

Instruction book
Compressors with Elektronikon® controller:
Check the display (2) regularly for readings and messages. The display normally shows the compressor
outlet pressure, while the status of the compressor is indicated by pictographs. Remedy the trouble if alarm
LED (7) is lit or flashes, see section
will show a service message if a service plan interval has been exceeded or if a service level for a
monitored component has been exceeded. Carry out the service actions of the indicated plans or replace the
component and reset the relevant timer, see section
5.6

Stopping

Elektronikon regulator
Procedure
Step
-
-
-
-
API459842
Shutdown warning
Control panel Elektronikon®
Action
Press stop button (9). Automatic operation LED (8) goes out and the compressor stops
after a programmed number of seconds of unloaded operation (programmed stop time).
To stop the compressor in the event of an emergency, press emergency stop button
(10). Alarm LED flashes (7).
On compressors with an Elektronikon® controller: remedy the problem cause, unlock
the button by pulling it out or by rotating it (dependent on the model) and press the
Escape button (5) to reset.
Do not use emergency stop button (10) for normal stopping!
Close air outlet valve (AV), see section Introduction.
Open the manual drain (Dm).
Switch off the voltage.
,
Shutdown
and
Problem
Service
warning.
solving. The display (2)