Oil System - Atlas Copco GA 15 Instruction Book

Hide thumbs Also See for GA 15:
Table of Contents

Advertisement

Instruction book
Description
Air drawn through filter (AF) and open inlet valve (IV) into compressor element (E) is compressed.
Compressed air and oil flow into the oil tank (OT). The air is discharged through outlet valve (AV) via
minimum pressure valve (Vp) and air cooler (Ca).
During loaded operation, minimum pressure valve (Vp) keeps the pressure in the separator tank (OT)
above a minimum value, required for lubrication. An integrated check valve prevents the compressed air
downstream the valve from being vented to atmosphere during unloaded operation.
When the compressor is stopped, inlet valve (IV) closes, preventing compressed air and oil to be vented
into the air filter.
A condensate trap (MT) downstream the air cooler is included.
On Full-Feature compressors, the air flows through air dryer (DR) before it is discharged through outlet
valve (AV). Also see section
2.3

Oil system

Flow diagram
API459842
Air dryer .
Oil system
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents