Control Panel - Atlas Copco GA 15 Instruction Book

Hide thumbs Also See for GA 15:
Table of Contents

Advertisement

If one of the measurements exceeds the programmed shutdown warning level, this will also be indicated to
warn the operator before the shutdown level is reached.
Service warning
If the service timer exceeds a programmed value, this will be indicated on the display to warn the operator
to carry out some service actions.
Other warnings
On compressors equipped with an integrated dryer, a warning message will appear if the dew point is too
high or too low for the given ambient temperature.
Automatic restart after voltage failure
The controller has a built-in function to automatically restart the compressor when the voltage is restored
after voltage failure. For compressors leaving the factory, this function is made inactive. If desired, the
function can be activated. The ARAVF label 1079 9932 74 ( see section Pictographs ) shall be glued near
to the controller. Consult your local supplier.
3.2

Control panel

Detailed description
Reference
1
2
26
If activated, and if the regulator was in the automatic operation mode, the compressor
will automatically restart when the supply voltage to the module is restored!
Control panel of the Elektronikon controller
Designation
Display
Automatic operation symbol
Function
Shows icons and operating conditions.
Instruction book
API459842