Instruction book
5.4

During operation

Warnings
Checking the oil level
Regularly check the oil level. To do this, press the stop button (9). Three minutes after stopping, sight-glass
(Gl) should be between 1/4 and 3/4 full.
If the oil level is too low, press the emergency stop button (10), close the air outlet valve and open (if
provided) the manual condensate drains. See section
location of the outlet valve and the water drain. Next, depressurise the oil system by unscrewing oil filler
plug (FC) one turn and wait a few minutes. Remove the plug and top up oil, until the sight-glass is full. Fit
and tighten the plug (FC).
API459842
The operator must apply all relevant
solving.
Removing the front panel (service panel) during operation will lead to an automatic
shutdown of the unit after a certain time depending of the compressor version.
When the motors are stopped and LED (8) (automatic operation) is alight, the motors may
start automatically.
When the automatic operation LED (8) is lit, the regulator is automatically controlling the
compressor, i.e. loading, unloading, stopping of the motors and restarting!
Control panel Elektronikon®
Safety
precautions. Also consult section
Introduction
and section
Problem
Condensate system
for
77