Recommendations
1. Never remove the filtration element while the compressor is running.
2. For minimum downtime, replace the dirty element by a new one.
3. Discard the element when damaged.
Procedure
1. Stop the compressor. Switch off the voltage.
2. On Pack units: remove the side panel.
On Full-Feature units: remove the front panel.
3. Remove the air filter assembly.
4. Remove the cover of air filter (AF) by turning it anti-clockwise. Remove the filter element. If
necessary, clean the cover.
5. Fit the new element and the cover.
6. Reset the air filter service warning.
For compressors equipped with an Elektronikon® regulator, see section
1. Stop the compressor. Switch off the voltage.
2. Remove the side panel.
3. Remove the cover of air filter (AF) by turning it anti-clockwise. Remove the filter element. If
necessary, clean the cover.
4. Fit the new element and the cover.
5. Reset the air filter service warning.
For compressors equipped with an Elektronikon® regulator, see section
7.3
Oil and oil filter change
Warning
86
The operator must apply all relevant
Always drain the compressor oil at all drain points. Used oil left in the compressor can
contaminate the oil system and can shorten the lifetime of the new oil.
Never mix lubricants of different brands or types as they may not be compatible and the
oil mix will have inferior properties. A label, indicating the type of oil filled ex-factory, is
stuck on the air receiver/oil tank.
Service
Service
Safety
precautions.
Instruction book
warning.
warning.
API459842