11Adjust Transmission Sensor - Brother TD-2020 Service Manual

Hide thumbs Also See for TD-2020:
Table of Contents

Advertisement

1.2.11 Adjust Transmission Sensor
Adjusts sensor read value to allow transmission sensor to detect label and separator. Also
checks cover sensor function when the cover is opened or closed. 80GS OJI roll ASSY must be
used for sensor adjustment. Cut the media in advance as it is wider than the machine. Also,
make sure that the sensor is positioned properly. Starting inspection with wrongly positioned
sensor would cause shipment of product which is unable to detect media gap.
Model
TD-2000
TD-2100N
(1)
Open the cover of the machine to set 80GS OJI roll ASSY to the sensor read section and
close the cover. Set the roll ASSY so that the gloss surface of the media faces up.
(2)
Make sure that the "Adjust transmission sensor" field is highlighted in yellow and press
the [Run] button to start the inspection.
Inspection
Valid
Valid
Figure 17. Correct position of the sensor
Figure 18. "Adjust transmission sensor" start-up
1 - 14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Td-2120nTd-2130n

Table of Contents