4.3 Inspection and cleaning

4.3.1 Prior to heating up

4.3.2 Inspection

Checking the system pressure

34
Not included:
9
Spanner or box wrench AF 10
10
Spanner or box wrench AF 13
11
Screwdriver set (Philips, flat head, Torx T20)
12
Small brush or cleaning brush
13
Ash vacuum
❒ Regular cleaning of the boiler extends its life and is a basic requirement for
smooth running.
❒ Recommendation: use an ash vacuum for cleaning.
Always move the WOS lever
❒ Move the lever of the cleaning system several times before the heating-up process
(5-10 times up and down)
❒ Check the system pressure on the pressure gauge
➥ The value must be 20% above the pre-stressed pressure of the expansion tank
NOTICE! Check that the position of the pressure gauge and rated pressure of
the expansion tank match your installer's specifications!
If the system pressure decreases:
❒ Top up with water
NOTICE! If this happens frequently, the seal of the heating system is faulty! Inform
your installer
If large pressure fluctuations are observed:
❒ Ask an expert to inspect the expansion tank
Fröling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com
Boiler servicing
Inspection and cleaning

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SP Dual compact and is the answer not in the manual?

This manual is also suitable for:

S1 turbo

Table of Contents