Fuel Table; Fill Level In Boiler; Reloading Intervals When Operating Without Storage Tank Or If The Storage Tank Is Too Small - Froling SP Dual compact Operating Instructions Manual

Dual fuel boiler
Hide thumbs Also See for SP Dual compact:
Table of Contents

Advertisement

3

Fuel table

Fill level in boiler

Reloading intervals when operating without storage tank or if the storage tank is too
small
26
The table below shows a selection of wood types with the corresponding energy
content depending on the water content:
Wood type
Spruce
Pine
Beech
Oak
The table below shows the relationship between fill level and weight. It compares
beech (example of hardwood) and spruce (example of soft wood) with a water content
of approx. 20%. Using our example above with beech, the fill level of an S1 Turbo 15
would, therefore, be approximately two-thirds.
Fill level
3/3
Beech
Spruce
2/3
Beech
Spruce
1/3
Beech
Spruce
Feed based on output:
Only replenish the fuel if energy is needed!
❒ If too much fuel is loaded, the boiler drops below its minimum output limit and
goes over to "constant burn" operating status (blower fan switches off)
➥ The level of efficiency drops in constant burn mode, the emissions
increase and the boiler can tar up (pitch formation!)
Fröling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com
Energy content with water content [kWh/kg]
w = 15%
w = 20%
4.3
4.3
4.1
4.1
Weight at fill level
S1 Turbo 15/20
approx. 28 kg
approx. 17 kg
approx. 19 kg
approx. 12 kg
NOTICE
Operating the system
Heating up the boiler
w = 25%
4.0
3.7
4.0
3.7
3.8
3.5
3.8
3.5
approx. 9 kg
approx. 6 kg