Vega VEGAPULS 62 Operating Instructions Manual page 59

Universally implementable radar level transmitter for continuous level 4...20 ma/hartmeasurement of liquids
Hide thumbs Also See for VEGAPULS 62:
Table of Contents

Advertisement

Supplement
Electromechanical data
Cable entry/plug
6)
- single chamber housing
- double chamber housing
Spring-loaded terminals
Indicating and adjustment module PLICSCOM
Power supply and data transmis-
sion
Indication
Adjustment elements
Protection
- unassembled
- mounted into the sensor without
cover
58
1x cable entry M20x1.5 (cable-ø
l
5 ... 9 mm), 1x blind stopper M20x1.5
or:
1 x closing cap ½ NPT, 1 x blind
l
stopper ½ NPT
or:
1x plug (depending on the version), 1x
l
blind stopper M20x1.5
1 x cable entry M20x1.5 (cable-ø
l
5 ... 9 mm), 1 x blind stopper M20x1.5,
plug M12x1 for VEGADIS 61 (option)
or:
1x closing cap ½ NPT, 1x blind stopper
l
½ NPT, plug M12x1 for VEGADIS 61
(option)
or:
1x plug (depending on the version), 1x
l
blind stopper M20x1.5, plug M12x1 for
VEGADIS 61 (option)
for wire cross sections up to 2.5 mm²
through sensor via gold-plated sliding
contacts (I²C bus)
LC display in dot matrix
4 keys
IP 20
IP 40
depending on the version M12x1, acc. to DIN 43650, Harting,
6)
Amphenol-Tuchel, 7/8" FF
VEGAPULS 62 - 4 ... 20 mA/HART