Supplement
Characteristics curve deviation and measurement characteristics
Average temperature coefficient of
the zero signal (temperature error)
Resolution, general
Frequency
Interval
Beam angle with horn antenna, depending on the antenna diameter
- ø 40 mm
- ø 48 mm
- ø 75 mm
- ø 95 mm
Beam angle with parabolic antenna
Adjustment time
3)
Max. emitted power
Received average emitted power reaching an object directly in front of the antenna
- distance 1 m
- distance 5 m
Accuracy
10 mm
3 mm
-3 mm
-10 mm
Fig. 33: Accuracy VEGAPULS 62
56
0.06 %/10 K
max. 1 mm
K-band (26 GHz technology)
approx. 1 s
22°
18°
10°
8°
3.5°
> 1 s (dependent on the parameter
adjustment)
< 25 mW EIRP
0.4 ... 3.2 nW per cm² (0.4 ... 3.2 x 10
W/cm²)
0.02 ... 0.13 nW per cm² (0.02 ... 0.13 x 10
9
W/cm²)
see diagram
0,5 m
Relating to the nominal range, incl. hysteresis and repeatability,
2)
determined acc. to the limit point method.
Time to output the correct level (with max. 10 % deviation) after a
3)
sudden level change.
EIRP: Equivalent isotropically radiated power.
4)
2)
4)
30 m
VEGAPULS 62 - 4 ... 20 mA/HART