Lennox CLIMATIC series User Manual page 92

Baltic, flexy, flexair, energy, aircoolair, compactair, flatair, aqualean
Table of Contents

Advertisement

Menu
3221 offset for room temperature value
3222 room temperature threshold for unloading cooling mode
3223 room temperature threshold for unloading heating mode
3224 external value of set point for control temperature
3225 Dynamic set point (cooling setpoint offset according to outside temperature)
3226 set point of cooling mode
3227 set point of heating mode
3228 integral time control for cooling mode
3229 integral time control for heating mode
3231 activation of the smoothing function of temperature
3232 low limit threshold in cooling mode
3233 high limit threshold in heating mode
3234 offset for high limit threshold in cooling mode
3235 offset for low limit threshold in heating mode
3236 outdoor temperature low threshold for slope on the supply temperature setpoint
3237 coefficient of the low outside temperature for the slope of the supply temperature setpoint
3238 outdoor temperature high threshold for slope on the supply temperature setpoint
3239 coefficient of the high outside temperature for the slope of the supply temperature setpoint
3241 setpoint for activation operation of control
3242 set point of dehumidification
3243 set point of humidification
3244 integral time control for dehumidification
3245 integral time control for humidification
3251 lower supply temperature threshold, 1st level of alarm
3252 lower supply temperature threshold, 2nd level of alarm
3253 upper supply temperature threshold, 1st level of alarm
3254 upper supply temperature threshold, 2nd level of alarm
3255 lower room temperature threshold of alarm
3256 upper room temperature threshold of alarm
3257 dew point control
3258 lower room humidity threshold of alarm
3259 upper room humidity threshold of alarm
3261 state of unload cooling mode by BMS
3262 state of unload cooling mode by BMS
3263 value of the outside temperature send by BMS
3264 value of the room temperature send by BMS
3265 value of the outside humidity send by BMS
3266 value of the room humidity send by BMS
3311 choice of air flow sensor
3312 choice of inverter
3313 choice of kit
3314 choice of motor size
3315 choice of fan type
3321 setpoint for activation operation of component
3322 setpoint for activation operation in room control dead zone
3323 temperature threshold for activation night refreshment function
3324 time, cyclic dead zone function, fan on
3325 time, cyclic dead zone function, fan off
CLIMATIC RT_UNITARY‐IOM‐1508‐E
Description
4th digit
3rd digit
2nd digit
Expert
Control
Room
Expert
Control
Supply
Expert
Control
Humidity
Expert
Control
Safety
Expert
Control
Bms
Expert
Blower
Configuration
Expert
Blower
Mode
1st digit
R/W/Z Min
Std
Offset
R/W
‐5
Limit C.
R/W
0
Limit H.
R/W
0
40
4‐20mA
R
‐5
Sp.Dyna.
R/W/Z
0
20
Sp.Cool.
R/W/Z
8
22
Sp.Heat.
R/W/Z
8
19
Ti.Cool.
R/W
10
60
Ti.Heat.
R/W
10
60
Smooth
R/W/Z
0
Lim.Cool
R/W
4
Lim.Heat
R/W
4
38
Adj.Cool
R/W
‐5
Adj.Heat
R/W
‐5
Out.Low
R/W
‐20
Coef.Low
R/W
‐50
Out.High
R/W
‐20
30
Coef.High
R/W
‐50
Enable
R/W/Z
0
Sp. Deh.
R/W/Z
0
100
Sp. Hum.
R/W/Z
0
Ti. Deh.
R/W
10
60
Ti. Hum.
R/W
10
60
Sup Lo.1
R/W
5
Sup Lo.2
R/W
1
Sup Hi.1
R/W
20
40
Sup Hi.2
R/W
20
60
Room Lo.
R/W
5
Room Hi.
R/W
5
40
DewPoint
R/W
0
Room Lo.
R/W
0
Room Hi.
R/W
0
100
Cool.Mod
R/W
0
Heat.Mod
R/W
0
Out. T.
R/W
‐99,9
‐99,9
Room T.
R/W
‐99,9
‐99,9
Out. Hr.
R/W
0
Room Hr.
R/W
0
AirFlow
R/W
0
Modul.
R/W
0
Kit
R/W
0
Motor
R/W
0
Fan
R/W
0
Enable
R/W/Z
0
Dead Z.
R/W/Z
0
Night Eco
R/W
8
22
Time On
R/W
0
300
Time Off
R/W
0
3300
Max
0
5
0
40
40
0
5
20
35
35
120
120
0
1
4
58
58
0
5
0
5
0
50
0
50
50
0
50
0
1
100
0
100
120
120
6
19
2
17
70
70
5
40
40
0
1
0
100
100
0
1
0
1
99,9
99,9
0
100
0
100
0
1
0
2
0
5
0
10
0
4
1
1
0
2
35
32400
32400
. 90 .