Lennox CLIMATIC series User Manual page 70

Baltic, flexy, flexair, energy, aircoolair, compactair, flatair, aqualean
Table of Contents

Advertisement

BMS
APPENDIX 2
Lonworks
NV_Name
DESCRIPTION
nvi_Watchdog
bms, watchdog counter
nvo_Watchdog
alarm, codes
nvo_Alarm_Codes
nvo_Blower_Qv
blower, calculated value of air fl ow
blower, value of differential pressure sensor on air fl ow
nvo_Blower_dP
nvo_Room_Temp
control, value of the room temperature
control, value of the outside temperature
nvo_Outside_Temp
nvo_Supply_Temp
control, value of the supply temperature
nvo_Room_Hr
control, value of the room humidity
control, value of the outside humidity
nvo_Outside_Hr
nvo_CO2
economizer, value of air quality sensor
nvi_Control_Temp
control, customer (DC/DM) set point
nvo_Control_Temp
nvo_Control_Cool
control, set value of cooling mode
nvo_Control_Heat
control, set value of heating mode
nvi_Cool_BMS
control, bms day, set point of cooling mode
nvo_Cool_BMS
nvi_Heat_BMS
control, bms day, set point of heating mode
nvo_Heat_BMS
nvi_Cool_D
control, bms night, set point of cooling mode
nvo_Cool_D
nvi_Heat_D
control, bms night, set point of heating mode
nvo_Heat_D
nvi_Air_Mini_BMS
economizer, bms day, set point of minimum fresh air
nvo_Air_Mini_BMS"
nvi_Sends_Room_T
emulation, value of the room temperature send by bms
nvi_Sends_Out_T
emulation, value of the outside temperature send by bms
nvi_Sends_Room_H
emulation, value of the room humidity send by bms
nvi_Sends_Out_H
emulation, value of the outside humidity send by bms
nvi_Sends_CO2
emulation, value of the air quality send by bms
nvi_Sends_Speed
emulation, value of the speed blower send by bms
nvo_PM_kW
power meter, value of the active power
nvo_PM_kVA
power meter, value of the reactive power
nvo_PM_Pw_Factor
power meter, value of the power factor
nvo_PM_kWh_LSB
power meter, value (weight low) of the active energy
nvo_PM_kWh_MSB
power meter, value (weight high) of the real energy
nvo_PM_kVAh_LSB
power meter, value (weight low) of the reactive energy
nvo_PM_kVAh_MSB
power meter, value (weight high) of the reactive energy
nvi_PM_Reset
power meter, value for reset memory
nvo_Fresh_Air
economizer, opening percentage send to the actuator
nvo_Compressor
circuit, power percentage calculated
nvo_Heaters_1
1st heaters, power percentage calculated
nvo_Heaters_2
2nd heaters, power percentage calculated
nvo_Custom_T_1
remote control, value of the signal, be-1 b1, temperature
nvo_Custom_T_2
remote control, value of the signal, be-1 b2, temperature
nvo_Custom_T_3
remote control, value of the signal, be-1 b3, temperature
nvo_Custom_T_4
remote control, value of the signal, be-1 b4, temperature
• 68 •
MIN
FACT.
MAX
0
0
32767
0
~
999
0
~
32767
0
~
1000
-99.9
~
99.9
-99.9
~
99.9
-99.9
~
99.9
0.0
~
100.0
0.0
~
100.0
0
~
2000
8.0
20.5
35.0
8.0
~
35.0
8.0
~
35.0
8.0
22.0
35.0
8.0
19.0
35.0
8.0
35.0
35.0
8.0
15.0
35.0
0.0
20.0
100.0
-99.9
-99.9
99.9
-99.9
-99.9
99.9
0
0
100
0
0
100
0
0
2000
0.0
0.0
100.0
0
~
65536
0
~
65536
0
~
65536
0
~
65536
0
~
65536
0
~
65536
0
~
65536
0
0
65536
0.0
~
100.0
0.0
~
100.0
0.0
~
100.0
0.0
~
100.0
-99.9
~
99.9
-99.9
~
99.9
-99.9
~
99.9
-99.9
~
99.9
CLIMATIC RT_UNITARY-IOM-1508-E

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents