Lennox CLIMATIC series User Manual page 91

Baltic, flexy, flexair, energy, aircoolair, compactair, flatair, aqualean
Table of Contents

Advertisement

Menu
3131 setting of functionality for digital input bm id4
3132 setting of functionality for digital input bm id7
3133 setting of functionality for digital input be‐1 id1
3134 setting of functionality for digital input be‐1 id2
3135 setting of functionality for digital input be‐1 id3
3136 setting of functionality for digital input be‐1 id4
3141 setting of functionality for analog input be‐1 b1
3142 setting of functionality for analog input be‐1 b2
3143 setting of functionality for analog input be‐1 b3
3144 setting of functionality for analog input be‐1 b4
3145 threshold temperature for 4ma external sensor
3146 threshold temperature for 20ma external sensor
3151 DC60/ DM60 Configuration
3152 selecting the display mode for set point (k or °c)
3153 lower threshold temperature for set point customer
3154 upper threshold temperature for set point customer
3155 activation of the authorization to use old display or standard carel
3171 address of the unit (bus id)
3172 setting the sub‐bus
3173 setting the master of the bus
3174 number of compressors for token function or number of units
3175 setting of functionality
3176 activation of the function slaves works like master
3177 choice of outside temperature management
3178 choice of room temperature management
3179 choice of air quality management
3181 address of the unit (bus id)
3182 setting of the protocol type
3183 configuration of communication bus speed
3184 watchdog timer
3191 management of set points
3192 reserved for technicians lennox
3211 choice of the control (room temperature or supply)
3212 advanced control pack configuration
3213 choice of the room sensor temperature
3214 choice of the outside sensor temperature
3215 choice of the room sensor humidity
3216 choice of the outside sensor humidity
3217 choice of the supply air temperature sensor
CLIMATIC RT_UNITARY‐IOM‐1508‐E
Description
4th digit
3rd digit
2nd digit
Expert
Unit
Cust. Switch
Expert
Unit
Cust. Signal
Expert
Unit
Dc‐Dm
Expert
Unit
Master/Slaves
Expert
Unit
Bms
Expert
Unit
Lennox
Expert
Control
Configuration
1st digit
R/W/Z Min
Std
Bm‐iD4
R/W
30
30
Bm‐iD7
R/W
30
30
Be.1‐iD1
R/W
30
30
Be.1‐iD2
R/W
30
30
Be.1‐iD3
R/W
30
30
Be.1‐iD4
R/W
30
30
Be.1‐B1
R/W
30
30
Be.1‐B2
R/W
30
30
Be.1‐B3
R/W
30
30
Be.1‐B4
R/W
30
30
T.  4mA
R/W
‐99,9
‐40
T. 20mA
R/W
‐99,9
80
Remote
R/W
0
Sp Cust.
R/W
0
Low Sp
R/W
8
17
High Sp
R/W
8
27
DS Lennox
R/W
0
Address
R
1
Bus
R/W
1
Master
R/W
0
Number
R/W
0
Function
R/W
0
Together
R/W
0
Outside
R/W
0
Room
R/W
0
Air Q.
R/W
0
Address
R/W
1
Type
R/W
0
Baud
R/W
0
Watchdog
R/W
0
Restore
R/W
0
Tests
R/W
7
Mode
R/W
0
Humidity
R/W
0
Room T.
R/W
1
Out. T.
R/W
1
Room Hr.
R/W
1
Out. Hr.
R/W
1
Supply
R/W
1
Max
66
66
66
66
66
66
39
39
39
39
99,9
99,9
0
1
0
1
35
35
0
1
1
24
1
24
0
24
0
96
0
4
0
1
0
2
0
2
0
2
1
207
2
6
3
4
0
32767
0
5
7
48
0
1
0
1
2
511
1
63
1
511
1
63
1
3
. 89 .