Olivetti d-Color MF2613 Plus Service Manual page 92

Multifuction digital
Table of Contents

Advertisement

Item No.
U625
Setting the transmission system 1
Description
Makes settings for the auto redialing interval and the number of times of auto redialing.
Purpose
Change the setting to prevent the following problems: fax transmission is not possible due to too
short redial interval, or fax transmission takes too much time to complete due to too long redial
interval.
Method
1. Press the start key.
2. Select the item to be set.
Display
Interval
Times
Setting the auto redialing interval
1. Change the setting using the cursor left/right keys.
Description
Redialing interval
2. Press the start key. The value is set.
Setting the number of times of auto redialing
1. Change the setting using the cursor left/right keys or numeric keys.
Description
Number of redialing
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Service Manual
Description
Description
Setting the auto redialing interval
Setting the number of times of auto redialing
Setting range
1 to 9 (min.)
Setting range
0 to 15
1-3-54
2PX/2PY
Initial setting
3 (120 V)/2 (220-240 V)
Initial setting
2 (120 V)/3 (220-240 V)
Y116670-7