Olivetti d-Color MF2613 Plus Service Manual page 347

Multifuction digital
Table of Contents

Advertisement

Connector
Pin
YC5
1
Connected to
2
drum PWB Y
3
4
5
6
7
8
YC6
1
Connected to
2
developing
3
PWB K
4
YC7
1
Connected to
2
developing
3
PWB M
4
YC10
1
Connected to
2
developing
3
PWB C
4
YC13
1
Connected to
2
developing
3
PWB Y
4
Y116670-7
Signal
I/O
GND
-
EECLK
O
ERASEYDR
O
EEDATA
I/O
N.C.
-
+3.3V2
O
DA0
-
DA1
-
GND
-
TNSENK
I
+3.3V2
O
DLPTHERM
I
GND
-
TNSENM
I
+3.3V2
O
N.C.
-
GND
-
TNSENC
I
+3.3V2
O
N.C.
-
GND
-
TNSENY
I
+3.3V2
O
N.C.
-
Voltage
-
Ground
0/3.3 V DC (pulse) EEPROM clock signal
0/24 V DC
CL-Y: On/Off
0/3.3 V DC (pulse) EEPROM data signal
-
Not used
3.3 V DC
3.3 V DC power to DRPWB-Y
-
Ground
-
Ground
-
Ground
Analog
TS-K detection voltage
3.3 V DC
3.3 V DC power to DEVPWB-K
Analog
DEVTH detection voltage
-
Ground
Analog
TS-M detection voltage
3.3 V DC
3.3 V DC power to DEVPWB-M
-
Not used
-
Ground
Analog
TS-C detection voltage
3.3 V DC
3.3 V DC power to DEVPWB-C
-
Not used
-
Ground
Analog
TS-Y detection voltage
3.3 V DC
3.3 V DC power to DEVPWB-Y
-
Not used
2-3-23