Item No.
U425
Set Target
Description
Enters the lab values that is indicated on the back of the chart (P/N: AVGR23234P) used for
adjustment.
Purpose
Performs data input in order to correct for differences in originals during automatic adjustment.
Method
1. Press the start key.
2. Select the item to be set
Display
Table
DP
Method: Table
1. Press the start key.
2. Select the item to be set..
Display
White
Black
Gray1
Gray2
Gray3
C
M
Y
R
G
B
Adjust Original
3. Select the item to be set.
Display
L
a
b
4. Enters the value that is indicated on the back of the chart using the cursor right/left keys or
numeric keys.
5. Press the start key. The value is set.
Y116670-7
Description
Setting the value of the table adjustment.
Setting the value of DP adjustment.
Description
Setting the white patch for the original for adjustment
Setting the black patch for the original for adjustment
Setting the Gray1 patch for the original for adjustment
Setting the Gray2 patch for the original for adjustment
Setting the Gray3 patch for the original for adjustment
Setting the cyan patch for the original for adjustment
Setting the magenta patch for the original for adjustment
Setting the yellow patch for the original for adjustment
Setting the red patch for the original for adjustment
Setting the green patch for the original for adjustment
Setting the blue patch for the original for adjustment
Setting the main and auxiliary scanning directions
Description
Setting the L value
Setting the a value
Setting the b value
Description
Setting range
Initial setting
0.0 to 100.0
-200.0 to 200.0
-32.8/69.9/-18.6/54.2/-51.3/25.3
-200.0 to 200.0
-11.5/-6.1/81.7/38.6/48.9/-22.8
1-3-43
93.6/10.6/76.2/25.2/51.3
72.6/48.1/86.2/46.7/67.8/38.8
0.9/-0.2/-0.2/-0.2/-0.3
-0.4/-0.7/1.2/-0.2/0.3