Olivetti d-Color MF2613 Plus Service Manual page 349

Multifuction digital
Table of Contents

Advertisement

Connector
Pin
YC1
1
Connected to
2
main PWB
3
4
5
6
YC2
1
Connected to
2
DP open/
3
close sen-
4
sor, DP origi-
nal sensor
5
and DP tim-
6
ing sensor
7
8
9
YC3
1
Connected to
2
DP paper
3
feed motor
4
YC4
1
Connected to
2
DP pressure
3
solenoid
YC5
1
Connected to
2
DP switch-
back sole-
noid
YC6
1
Connected to
2
DP paper
feed clutch
Y116670-7
Signal
I/O
MOTA1
I
MOTB1
I
MOTA2
I
MOTB2
I
+24V2
I
GND
-
+3.3V2
O
GND
-
OPSWN
I
+3.3V2
O
GND
-
ORGSWN
I
+3.3V2
O
GND
-
TIMSWN
I
DPMOT1A
O
DPMOT2A
O
DPMOT1B
O
DPMOT2B
O
+24V2
O
PRESOLN
O
RELSOLN
O
+24V2
O
REVSOL
O
+24V2
O
FEEDCL
O
Voltage
0/24 V DC (pulse)
DPPFM drive control signal
0/24 V DC (pulse)
DPPFM drive control signal
0/24 V DC (pulse)
DPPFM drive control signal
0/24 V DC (pulse)
DPPFM drive control signal
24 V DC
24 V DC power from MPWB
-
Ground
3.3 V DC
3.3 V DC power to DPOCS
-
Ground
0/3.3 V DC
DPOCS: On/Off
3.3 V DC
3.3 V DC power to DPOS
-
Ground
0/3.3 V DC
DPOS: On/Off
3.3 V DC
3.3 V DC power to DPTS
-
Ground
0/3.3 V DC
DPTS: On/Off
0/24 V DC (pulse)
DPPFM drive control signal
0/24 V DC (pulse)
DPPFM drive control signal
0/24 V DC (pulse)
DPPFM drive control signal
0/24 V DC (pulse)
DPPFM drive control signal
24 V DC
24 V DC power to DPPRSOL
0/24 V DC
DPPRSOL: On (Press)/Off
0/24 V DC
DPPRSOL: On (Release)/Off
24 V DC
24 V DC power to DPSBSOL
0/24 V DC
DPSBSOL: On/Off
24 V DC
24 V DC power to DPPFCL
0/24 V DC
DPPFCL: On/Off
2-3-25
2PX/2PY
Description
Service Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-color mf2614 plus