0140
Backup memory data error
(main PWB)
0150
Engine PWB EEPROM error
Detecting engine PWB
EEPROM communication
error.
0170
Billing counting error
A checksum error is detected
in the main and engine
backup memories for the bill-
ing counters.
0180
Machine number mismatch
Machine number of main and
engine does not match.
0600
Expanded memory (DIMM)
installing error
The expansion memory mod-
ules (DIMM) are not correctly
mounted.
Service Manual
Causes
Defective flash
Replace the main PWB and check for cor-
memory.
rect operation (see page 1-5-30).
Defective main
Replace the main PWB and check for cor-
PWB.
rect operation (see page 1-5-30).
Improper installa-
Check the installation of the EEPROM and
tion engine PWB
remedy if necessary.
EEPROM.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-27).
Device damage of
Contact the Service Administrative Division.
EEPROM.
Data damage of
Contact the Service Administrative Division.
EEPROM.
Defective PWB.
Replace the main PWB or the engine PWB
and check for correct operation (see page 1-
5-30, 1-5-27).
Data damage of
Contact the Service Administrative Division.
EEPROM.
Improper installa-
Check the installation of the expanded mem-
tion expanded
ory (DIMM).
memory (DIMM).