(2) Detaching and refitting the operation panel
Procedure
1. Remove the operation panel right cover
by sliding forward.
2. Release three hooks and then remove
the operation panel.
3. Remove three connectors.
4. Check or replace the operation panel
and refit all the removed parts.
Service Manual
Hook
Hook
1-5-90
Operation panel
right cover
Figure 1-5-146
Operation panel
Connectors
Hook
Figure 1-5-147
2PX/2PY
Y116670-7