(2) Detaching and refitting the scanner unit

Procedure
1. Remove the document processor (see
page 1-5-78).
2. Remove the connector (YC36) and two
FFCs (YC8, YC43) from main PWB.
3. Open the scanner unit.
4. Remove the motor wire, CCD wire and
operation panel wires from the wire
holder.
Service Manual
YC36
Figure 1-5-72
CCD wire
Operation panel wires
Figure 1-5-73
1-5-48
Main PWB
YC8
Main PWB
Wire holder
Moter wire
2PX/2PY
YC43
Y116670-7