ABB FSM4000 Operating Instruction page 63

Electromagnetic flowmeter
Hide thumbs Also See for FSM4000:
Table of Contents

Advertisement

Submenu/parameter
Language
English
Language
English
Submenu
Operating mode
Operating mode
Standard
Flow indication
Standard
Noise reduction
Off
Flow direction
Forward/Reverse
Submenu
Unit
Unit totalizer
ml
D184B140U02
Value range
Comment
German
The languages available are displayed in the present
language selection. Menus in the Service Code section
English
are displayed in English.
French
Finnish
Spanish
Italian
Dutch
Danish
Swedish
Turkish
Standard
"Standard": Selection used for continuous flow metering.
Fast
"Fast": Accelerated processing of flowrate (e.g., short
batch operation).
Piston Pump
"Piston Pump": For pulsating flows. In this operating
mode, data logging improves reproducibility for pulsating
flows and during pump operation. The totalizer is
automatically set for the operating mode Difference
Totalizer. Any reverse flow that may occur is
automatically deducted from the totalizer value.
Standard, inverse
Standard/inverse, reverse the flow direction indicators in
the display for forward and reverse flow.
Off, 1, 2, 3, 4
The noise reduction is switched on when the measured
value is:
-
very unstable or
-
temporarily or permanently frozen (error E)
Note: Activating noise reduction increases the response
time.
Forward/Reverse
When the flow indication "Forward/Reverse" is selected,
the flow direction is indicated in the display by "→ F" for
Forward
forward and "← R" for reverse. If "Forward" is selected,
the totalizer only totalizes flow in the forward direction. If
the flow is reversed, warning 10 "Reverse Q" is displayed.
3
Select the engineering units for volume and mass flowrate
ml; l; m
; ugl; igl; bbl;
totalization. If these units are changed, the transmitter
g; kg; t; lb;
checks and updates the flow range, pulse factor and
; ft 3
1)
2)
Prog Unit
pulse width (0.1 ms ... 2000 ms). The transmitter first
changes the pulse factor and then the pulse width.
1) kgal = Factory setting
2) ft 3 = added only for PROFIBUS PA
FSM4000
Parameterization
63

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents