System Input Requirements; Operating Environment; Regulatory Compliance - Supero SUPERSERVER 1018GR-T User Manual

Table of Contents

Advertisement

SUPERSERVER 1018GR-T User's Manual
Serverboard
X10SRG-F (proprietary form factor)
Dimensions: 7.71" x 16.64" (196 x 423 mm)
Chassis
SC118G-1K43BP (1U rackmount)
Dimensions: (WxHxD) 17.2 x 1.7 x 30.6 in. (437 x 43 x 777 mm)
System Cooling
Eight sets of 4-cm counter-rotating cooling fans (fan speed controlled by IPMI)

System Input Requirements

AC Input Voltage: 100-240 VAC
Rated Input Current: 1200W: 100-140V/14.7-10.5A, 1400W: 180-140V/10.5-8.0A
Rated Input Frequency: 50-60 Hz
Power Supply
Rated Output Power: 1400W (Part# PWS-1K43F-1R)
Rated Output Voltages: at 1200W: +12V (100A), +5Vsb (6A), at 1400W: +12V
(117A), +5Vsb (6A)

Operating Environment

Operating Temperature: 10º to 35º C (50º to 95º F)
Non-Operating Temperature: -40º to 60º C (-40º to 140º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-Operating Relative Humidity: 5 to 95% (non-condensing)

Regulatory Compliance

Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-
3, CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and
Canada), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply.
See www.dtsc.ca.gov/hazardouswaste/perchlorate"
B-2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Superserver 5018gr-t

Table of Contents