A+ SERVER 2122TC-DL6RF4 USER'S MANUAL
Weight
Gross (Bare Bone): 85 lbs. (38.6 kg.)

System Cooling

Four 8-cm PWM system cooling fans

System Input Requirements

AC Input Voltage: 100-240V AC auto-range
Rated Input Current: 12 - 6A
Rated Input Frequency: 50 to 60 Hz
Efficiency: 94+ (Platinum Level)
Power Supply
Rated Output Power: 1280 Watts (Part# PWS-1K28P-SQ)
Rated Output Voltages: +12V (107A@180-264V, 183A@120-140V), +5Vsb (4A)

Operating Environment

Operating Temperature: 10º to 30º C (50º to 86º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 20% to 95% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)

Regulatory Compliance

Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-
3, CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and
Canada), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply.
See www.dtsc.ca.gov/hazardouswaste/perchlorate" for further details.