Installing The Server Into A Two Post Rack - Supero SUPERSERVER 1018GR-T User Manual

Table of Contents

Advertisement

Chapter 2 Installation in a Rack

Installing the Server into a Two Post Rack

Optional brackets (p/n MCP-290-00016-0N) are needed to install the server to a
two post (telco type) rack.
Use the two L-shaped brackets on either side of the chassis (four total). First,
determine how far follow the server will extend out the front of the rack. Larger
chassis should be positioned to balance the weight between front and back. If a
bezel is included on your server, remove it. Then attach the two front brackets to
each side of the chassis, then the two rear brackets positioned with just enough
space to accommodate the width of the telco rack. Finish by sliding the chassis into
the rack and tightening the brackets to the rack.
Figure 2-6. Installing the Server into a Telco Rack
Note: The figure above is for illustrative purposes only. Always install servers at
the bottom of the rack first.