Error codes

The Ember has self diagnostic electronics that monitor the appliance during
start up and operation. Should a fault occur the heater will shut down. The
fault that has caused the shut down will be indicated by a pair of flashing
numbers in the error display window in the lower left hand side of the frame.
The error will show through two narrow cutouts—you will need to walk up to
the fire and look down to see these.
Error
Likely cause
code
Mains power failure
00
Ignition failure
11
Incomplete combustion
12
Overheat safety device
14
Room overheat
16
Room temperature sensor faulty
31
Overheat temperature 1 sensor faulty
32
Overheat temperature 2 sensor faulty Service call.
33
Spark sensor faulty
53
Combustion fan motor faulty
61
Model error
70
Solenoids faulty
71
Flame detection circuit fault
72
Communication error
73
Ember - top view of frame, looking down
Error codes will show through
these slots in the frame
Suggested solution
Reset the fire, press the On/Off button on the control
panel or remote control twice to turn the fire back on.
Check the gas supply is turned on. Turn the heater OFF
then ON again. If the problem continues a service call
will be required.
As above.
Service call.
Lower room temperature to below 40 °C.
Service call.
Service call.
Service call.
Service call.
Incorrect PCB for model, service call.
Service call.
Service call.
Service call.
Infra-red remote receiver
window and ignition indicator