200SE-2S - 300SE-2S
5.5
Installer parameters
Parameter Description
Reference temperature
DT
difference
Self-calibration phase
tu
Set temperature of the
SX
solar calorifier
Maximum collector
CMAX
temperature
Minimum collector
CMIN
temperature
Collector antifreeze
OAC
option
Antifreeze function
TAON
activation temperature
Antifreeze function
TAOF
deactivation
temperature
Tubular collector option
FT
(1) The parameter is set to On if the S3 domestic hot water sensor is connected
26/04/2016 - 7607575-05
WARNING
Modifying the factory parameters may impair correct
operation of the solar DHW calorifer. The following
parameters must only be modified by a qualified
professional.
5.5.1.
1. Go forward to the last display channel (HRE) with the ) key.
2. Press the ) key for 5 seconds.
A setting parameter is displayed, with the symbol T .
3. Select a parameter using the ( and ) keys.
4. Briefly press the B key.
The symbol T flashes, the parameter can be set.
M000393-B
5. Modify the parameter using the ( and ) keys.
6. Press B to confirm the setting.
5.5.2.
Adjustment range Increment Factory
10/20 K
0.1
1 / 5 mn
1
4 / 80 °C
1
70 / 120 °C
1
10 / 90 °C
0.5
On / OFF
-4 / 5.5 °C
0.5
4.5 / 9 °C
0.5
On / OFF
Modifying the installer parameters
List of the parameters
Remarks
setting
¼See chapter: "Description of the
20
installer parameters", page 51
¼See chapter: "Description of the
3
installer parameters", page 51
¼See chapter: "Description of the
60
installer parameters", page 51
¼See chapter: "Description of the
110
installer parameters", page 51
¼See chapter: "Description of the
30
installer parameters", page 51
OFF
4
4
¼See chapter: "Description of the
installer parameters", page 51
4
Available if OAC = On
6
Available if OAC = On
OFF
4
4
¼See chapter: "Description of the
installer parameters", page 51
5. Commissioning
On: On
OFF: Off
On: On
OFF: Off
49