4. Installation
S1
R1
Reference Terminals Description
1-2
S1
3-4
S2
7
PWM
8
PWM
9-10
VBus
11-14
4
15
R1
16
N
17
N
20
L
36
Solar sensor probe - TC
DHW sensor, lower tank zone - TR PT1000 FR
PWM solar circulation pump
PWM solar circulation pump
DL2 connection
Earthing terminals
Solar circulation pump
Solar circulation pump
230 V main supply
230 V main supply
Diagram with solar circuit only:
S2
Connector / Sensor
PT1000 FK
-
+
Conductor - Green/Yellow
Live - Brown - (Cable provided)
Neutral - Blue - (Cable provided)
Neutral
Live
4.10.4.

Connecting the resistor

The electrical schematics above present a traditional connection with
permanent power supply to the control system. Connect an electrical
resistor with integrated thermostat to the electrical power only, without
going through the control system. Use a different mains supply for the
control system and the electrical resistor with integrated thermostat.
CAUTION
The forcing functions, set-point temperatures for the
backup and 3-position switch on the front of the control
system are not used with a resistor with integrated
thermostat.
200SE-2S - 300SE-2S
100 .. . 240 V~
M003205-A
26/04/2016 - 7607575-05