REMEHA RemaSol200SE-2S Installation And Service Manual

Solar hot water calorifer
Table of Contents

Advertisement

Quick Links

RemaSol
Solar hot water calorifer
200SE-2S - 300SE-2S
7607575-05
Installation and
Service Manual
EN

Advertisement

Table of Contents
loading

Summary of Contents for REMEHA RemaSol200SE-2S

  • Page 1 RemaSol Solar hot water calorifer 200SE-2S - 300SE-2S Installation and Service Manual 7607575-05...
  • Page 2: Declaration Of Conformity

    Declaration of conformity [ The device complies with the standard type described in the EG declaration of conformity. It was manufactured and commissioned in accordance with European directives. The original declaration of conformity is available from the manufacturer.
  • Page 3: Table Of Contents

    Contents Safety instructions ..................6 Safety instructions ..........6 Recommendations ..........8 Liabilities ...............9 1.3.1 Manufacturer’s liability ..........9 1.3.2 Installer’s liability ...........10 About this manual ..................11 Symbols used .............11 2.1.1 Symbols used in the manual .........11 2.1.2 Symbols used on the equipment ......11 Abbreviations ............11 Technical description ................12 Homologations ............12...
  • Page 4 Contents Choice of the location ........20 4.3.1 Type plate .............20 4.3.2 Positioning of the appliance ........20 4.3.3 Main dimensions ...........21 Positioning the appliance ........22 Levelling ..............22 Installing the temperature sensors ....22 Hydraulic installation diagrams ......23 4.7.1 Boiler for heating only (Output <45 kW) + 200/300SE-2S ............23 4.7.2 Combi boiler + 200/300SE-2S ......24...
  • Page 5 Commissioning procedure ........47 5.3.1 Secondary circuit (domestic water) .......47 5.3.2 Primary solar circuit ..........47 Reading out measured values ......48 5.4.1 Resetting the values to zero ........48 Installer parameters ..........49 5.5.1 Modifying the installer parameters ......49 5.5.2 List of the parameters ...........49 5.5.3 Description of the installer parameters ....51 Checking and maintenance ..............56...
  • Page 6 Contents Appendix – Information on the Ecodesign and Energy Labelling Directives ....................72 26/04/2016 - 7607575-05...
  • Page 7 26/04/2016 - 7607575-05...
  • Page 8: Safety Instructions

    1. Safety instructions 200SE-2S - 300SE-2S Safety instructions Safety instructions DANGER This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 9 200SE-2S - 300SE-2S 1. Safety instructions CAUTION Pressure limiter device 4 The pressure limiter device (safety valve or safety unit) must be operated regularly in order to clear out any limescale deposits and ensure that it is not blocked. 4 The pressure limiter device must be connected to a discharge pipe.
  • Page 10: Recommendations

    1. Safety instructions 200SE-2S - 300SE-2S CAUTION Respect the maximum water inlet pressure to ensure correct operation of the appliance, referring to the chapter "Technical Specifications". CAUTION Before any work, switch off the mains supply to the appliance. CAUTION In order to limit the risk of being scalded, the installation of a thermostatic mixing valve on the domestic hot water flow piping is compulsory.
  • Page 11: Liabilities

    200SE-2S - 300SE-2S 1. Safety instructions The instructions and warnings affixed to the appliance must never be removed or covered and must remain legible during the entire lifespan of the appliance. Immediately replace damaged or illegible instructions and warning stickers. WARNING Never cut the power to the solar control system, even during extended absences.
  • Page 12: Installer's Liability

    1. Safety instructions 200SE-2S - 300SE-2S 1.3.2. Installer’s liability The installer is responsible for the installation and commissioning of the appliance. The installer must respect the following instructions: 4 Read and follow the instructions given in the manuals provided with the appliance. 4 Carry out installation in compliance with the prevailing legislation and standards.
  • Page 13: About This Manual

    200SE-2S - 300SE-2S 2. About this manual About this manual Symbols used 2.1.1. Symbols used in the manual In these instructions, various danger levels are employed to draw the user’s attention to particular information. In so doing, we wish to safeguard the user’s safety, highlight hazards and guarantee correct operation of the appliance.
  • Page 14: Technical Description

    3. Technical description 200SE-2S - 300SE-2S Technical description Homologations 3.1.1. Certifications This product complies to the requirements to the european directives and following standards: PHRASE NON TRADUITE : 65228 Reference Standard: EN 60.335.1. Reference Standard: EN 60.335.2.21. PHRASE NON TRADUITE : 65229 Reference Standards: EN 50.081.1, EN 50.082.1, EN 55.014 3.1.2.
  • Page 15: Main Parts

    200SE-2S - 300SE-2S 3. Technical description Main parts 3.3.1. Solar domestic hot water calorifier 200SE-2S - 300SE-2S: External view Expansion vessel Top inspection trap Side inspection plate Solar station Solar regulator Electrical back-up (Option) Safety control unit for the solar circuit All components are checked for leaks and tested in the factory.
  • Page 16: Solar Station

    3. Technical description 200SE-2S - 300SE-2S 3.3.2. Solar station Pressure gauge Solar circulation pump Filling valve Draining valve Safety valve Solar circuit air vent Flowmeter Clamping ring fitting Red flow thermometer Blue flow thermometer L000415-C 3.3.3. Solar regulator Cover Alphanumeric LCD display Control keys Fuse 4 AT backup Connectors...
  • Page 17: General Principle

    200SE-2S - 300SE-2S 3. Technical description 3.4.1. General principle °C CMAX CMIN PC % M002751-C Temperature of the solar collectors Temperature of the lower part of the tank Reference temperature difference Set temperature of the solar calorifier Solar circulation pump mode PC % Minimum collector temperature triggering the pump CMIN...
  • Page 18: Protection Against Overheating On The Solar Circuit

    3. Technical description 200SE-2S - 300SE-2S Live Operating description When the temperature in the collectors reaches the maximum value (adjustment parameter CMAX, factory setting 110°C), the solar pump is triggered to cool the collectors. The pump continues to operate until the temperature in the collectors is lower than 5 K at parameter CMAX and/or the maximum storage temperature (80°C) is reached in the hot water storage tank.
  • Page 19: Sensor Characteristics

    200SE-2S - 300SE-2S 3. Technical description 200SE-2S 300SE-2S Performance Primary circuit: Back-up exchanger Power exchanged Performance litres per hour Flow per hour (∆T = 35 °C) litres per 10 min. Transfer capacity over 10 minutes (∆T = 30°C) kWh/24h Maintenance consumption (ΔT=45K) Performance N (1) Primary temperature: 80 °C - Domestic cold water inlet: 10 °C - Domestic hot water outlet: 45 °C - Primary flow rate: 2 m 3 /h (2) Primary temperature: 80 °C - Domestic cold water inlet: 10 °C - Domestic hot water outlet: 40 °C - Domestic hot water storage: 65 °C...
  • Page 20: Solar Station

    3. Technical description 200SE-2S - 300SE-2S 4 Tubular solar collector function. 4 Calorimetric balance. 4 Hourly command thermostat. 4 3-position switch. 3.5.4. Solar station Dimensions Spacer 100 mm Connections for pipes DN18 clamping ring screw connections Connection for expansion vessel 3/4 external thread (Sheet gasket) Outflow safety valve 3/4 internal thread...
  • Page 21: Installation

    200SE-2S - 300SE-2S 4. Installation Installation Regulations governing installation CAUTION Installation of the appliance must be done by a qualified engineer in accordance with prevailing local and national regulations. CAUTION France: The installation must comply in all matters to the standards and rules which govern the work and interventions in individual and collective homes, and other constructions.
  • Page 22: Choice Of The Location

    4. Installation 200SE-2S - 300SE-2S Choice of the location 4.3.1. Type plate The type plate must be accessible at all times. The type plate identifies the product and provides the following information: 4 DHW calorifier type 4 Manufacturing date (Year - Week) 4 Serial number.
  • Page 23: Main Dimensions

    200SE-2S - 300SE-2S 4. Installation 4.3.3. Main dimensions L000601-B Domestic hot water outlet G1" Circulation G¾" Exchanger inlet G1" Domestic hot water sensor Exchanger outlet G1" Domestic cold water inlet + Drain opening G1" Solar exchanger inlet DN18 Solar exchanger outlet DN18 Position solar sensor 200SE-2S 300SE-2S 70.5...
  • Page 24: Positioning The Appliance

    4. Installation 200SE-2S - 300SE-2S Positioning the appliance CAUTION Have 2 people available. Handle the appliance with gloves. 1. Remove the packaging from the DHW calorifier, leaving the calorifier on the pallet used for transport. 2. Remove the protective packaging. 3.
  • Page 25: Hydraulic Installation Diagrams

    200SE-2S - 300SE-2S 4. Installation Hydraulic installation diagrams 4.7.1. Boiler for heating only (Output <45 kW) + 200/300SE-2S C004578-B Wall-hung gas boiler (Calenta) 2 collectors running in parallel RemaSOL 200SE-2S RemaSOL 300SE-2S Solar station Domestic hot water outlet DHW calorifier exchanger primary inlet Domestic hot water circulation loop return Domestic hot water sensor DHW calorifier heat exchanger primary outlet...
  • Page 26: Combi Boiler + 200/300Se-2S

    4. Installation 200SE-2S - 300SE-2S D.H.W. loop back pump Domestic hot water thermostatic mixing valve iSense Safety unit Solar sensor probe Solar domestic hot water calorifier sensor Sensor option Optional outside sensors Primary solar circuit pump Boiler flow (Calenta solo) Boiler return (Calenta solo) 4.7.2.
  • Page 27: Combi Boiler + Additional Heating (Output <45 Kw) + 200/300Se-2S

    200SE-2S - 300SE-2S 4. Installation Integration option DHW calorifier exchanger primary inlet DHW calorifier heat exchanger primary outlet Connection kit for the solar tank Solar flow Solar return Solar regulator SOL AEL Safety unit Solar sensor probe Solar domestic hot water calorifier sensor Sensor option Optional outside sensors Primary solar circuit pump...
  • Page 28: Safety Unit

    4. Installation 200SE-2S - 300SE-2S Solar station Additional heat source (output <45 kW) Domestic hot water outlet Flow to external heat source Circulation piping connection (optional) Tank return to external heat source Domestic cold water inlet Integration option DHW calorifier exchanger primary inlet DHW calorifier heat exchanger primary outlet Connection kit for the solar tank Solar flow...
  • Page 29: Hydraulic Connections

    200SE-2S - 300SE-2S 4. Installation Hydraulic connections 4.9.1. Primary solar circuit CAUTION When switched off, the temperature in the collectors can exceed 150 °C. CAUTION To protect against frost, use a water-propylene glycol mixture as the heat transporting fluid. CAUTION Due to the high temperatures, the use of propylene glycol and the pressure in the primary solar circuit, the primary solar water connections must be made with the utmost...
  • Page 30 4. Installation 200SE-2S - 300SE-2S If the installation criteria for good degassing cannot be met, a manual bleed degasser R must always be installed at the high point(s) of the solar equipment. Ideal Incorrect (high point with no air vent) Correct (high point with air vent) Location of manual bleed valve degasser M001755-A...
  • Page 31 200SE-2S - 300SE-2S 4. Installation 4 If different copper pipes are used, the insulation must be: - Resistant to constant temperatures up to 150 °C in the collector zone and the hot outlet and also down to - 30 °C. - Insulation preferably waterproof and continuous.
  • Page 32 Airstop system at the bottom and bled out. The installation is once again fully operational. Thanks to the STEAMBACK safety system, Remeha solar installations are self-protecting and do not need to be drained or shut down during prolonged absences. The STEAMBACK...
  • Page 33: Primary Heating Circuit

    200SE-2S - 300SE-2S 4. Installation 4.9.2. Primary heating circuit Before connection, rinse the primary circuit to evacuate any particles that may damage certain devices (safety valve, pumps, valves, etc.). 4 Hydraulically isolate the primary and secondary circuits using stop valves to facilitate maintenance operations on the unit. The valves make it possible to carry out maintenance on the calorifer and its components without draining the entire installation.
  • Page 34 4. Installation 200SE-2S - 300SE-2S n Size 4 The diameter of the safety unit and its connection to the calorifer must be at least equal to the diameter of the domestic cold water inlet on the calorifer. 4 There must be no cut-off element between the valve or the safety unit and the domestic hot water calorifer.
  • Page 35: 4.10 Electrical Connections

    200SE-2S - 300SE-2S 4. Installation n Connecting the domestic cold water Make the connection to the cold water supply according to the hydraulic installation diagram. The components used for the connection to the cold water supply must comply with the prevailing standards and regulations in the country concerned.
  • Page 36: Connecting The Solar Control System

    4. Installation 200SE-2S - 300SE-2S 4 The instructions on the circuit diagrams provided with the appliance, 4 The manufacturer’s instructions. Belgium: The earthing must comply with the RGIE standard. Germany: The earth connection shall comply with standard VDE 0100. France: The earth connection shall comply with standard NFC 15-100.
  • Page 37 200SE-2S - 300SE-2S 4. Installation Diagram with solar circuit and electrical back-up: 100 .. . 240 V~ L000452-C Reference Terminals Description Connector / Sensor Solar sensor probe - TC PT1000 FK DHW sensor, lower tank zone - TR PT1000 FR DHW sensor - Electrical back-up - THR PT1000 FR PWM solar circulation pump PWM solar circulation pump...
  • Page 38: Connecting The Resistor

    4. Installation 200SE-2S - 300SE-2S Diagram with solar circuit only: 100 .. . 240 V~ M003205-A Reference Terminals Description Connector / Sensor Solar sensor probe - TC PT1000 FK DHW sensor, lower tank zone - TR PT1000 FR PWM solar circulation pump PWM solar circulation pump 9-10 VBus...
  • Page 39: Connecting The Circulation Pump

    200SE-2S - 300SE-2S 4. Installation 4.10.5. Connecting the circulation pump Carry out connection of the heating pump according to the instructions given in the above schematics and then select the pump type used (traditional pump or PWM) on the control system. ¼See chapter: "Description of the installer parameters", page 4.11 Filling the DHW calorifer CAUTION...
  • Page 40: 4.12 Filling The Primary Solar Circuit

    4. Installation 200SE-2S - 300SE-2S 4.12 Filling the primary solar circuit CAUTION To protect against frost, use a water-propylene glycol mixture as the heat transporting fluid. CAUTION check the connection to the series of collectors and the collector sensor connection. Antifreeze is included in the mixture.
  • Page 41: Anti-Thermosiphon Valve

    200SE-2S - 300SE-2S 4. Installation 4.12.2. Anti-thermosiphon valve 0° Position Operation Gravity brake in operation. 0° Stream only runs in direction of flow (arrow on the pipe). When the installation is running, the valves must be set back to the vertical position. Check the circulation on the flowmeter.
  • Page 42 4. Installation 200SE-2S - 300SE-2S n Flushing and sealing control The solar circuit is flushed in the normal flow direction, as shown by the arrow on the circulation pump. When commissioning, the solar installation must be flushed thoroughly to remove grit, deposits and any flux residue. Flushing time: 10 minutes Flushing fluid: Heat transporting fluid only The system must be tested for leaks with the heat transfer fluid when...
  • Page 43 200SE-2S - 300SE-2S 4. Installation CAUTION Do not carry out a leak test when the installation is exposed to direct solar radiation (risk of vaporisation) or when it is freezing (risk of damage). 1. Fully open the flow valve (45° position) C1. 2.
  • Page 44 4. Installation 200SE-2S - 300SE-2S The filling pressure must be more than 5 bar (0.5 MPa) above the expansion vessel pre-load pressure. The ready-to-use mixture must be pumped directly from the filling station. CAUTION Do not use a manual filling pump. Prolonged operation of the solar pump already brings about pre- degassing of the solar circuit.
  • Page 45: 4.13 Filling The Heating Circuit

    200SE-2S - 300SE-2S 4. Installation The air vented from the solar fluid is collected in the top of the air vent and can be evacuated via the vent plug. 1. Switch on the circulating pump. The air bubbles are directed towards the venting points.
  • Page 46: Commissioning

    5. Commissioning 200SE-2S - 300SE-2S Commissioning Control panels 5.1.1. Description of the keys Key ): Move the cursor upwards. Increase the value of parameter . Key B: Access a selected parameter. Confirm a value modification. Key (: M002759-A Move the cursor downwards. Reduce the parameter value.
  • Page 47 200SE-2S - 300SE-2S 5. Commissioning n Operating indicators Steady symbol Flashing State symbol Solar pump activated. Back-up activated. DHW calorifer set point temperature exceeded. M002761-A Cooling function of the collector or DHW calorifer activated. Antifreeze function activated. Antifreeze function active (running). Minumum collector temperature exceeded.
  • Page 48: Check Points Before Commissioning

    5. Commissioning 200SE-2S - 300SE-2S Check points before commissioning CAUTION If the temperature in the solar collectors is higher than 130°C, the control system operates in safety mode. Wait until the evening before start-up or cool down (cover) the solar collectors. 5.2.1.
  • Page 49: Commissioning Procedure

    200SE-2S - 300SE-2S 5. Commissioning Commissioning procedure WARNING Initial commissioning must be done by a qualified professional. During the heating process, water can flow through the bleed circuit to guarantee the safety of the installation. This phenomenon is perfectly normal and must in no circumstances be hindered.
  • Page 50: Reading Out Measured Values

    5. Commissioning 200SE-2S - 300SE-2S The regulator starts an initialisation phase during which the LED flashes red and green. When initialisation is complete, the regulator changes to automatic mode. To initiate the solar pump, a minimum temperature of 30 °C is required at the collector and a temperature difference of 6 °C with respect to the domestic hot water calorifier.
  • Page 51: Installer Parameters

    200SE-2S - 300SE-2S 5. Commissioning Installer parameters WARNING Modifying the factory parameters may impair correct operation of the solar DHW calorifer. The following parameters must only be modified by a qualified professional. 5.5.1. Modifying the installer parameters 1. Go forward to the last display channel (HRE) with the ) key. 2.
  • Page 52 5. Commissioning 200SE-2S - 300SE-2S Parameter Description Adjustment range Increment Factory Remarks setting Pump command mode OnOF / PuLS / PSOL OnOF: Heating pump ON or OFF POMP PSOL (0% or 100%) PuLS: Pump modulation from 50% to 100% PSOL: PWM solar-controlled heating pump Minimum solar pump 20 / 100%...
  • Page 53: Description Of The Installer Parameters

    200SE-2S - 300SE-2S 5. Commissioning 5.5.3. Description of the installer parameters n Reference temperature difference - DT The regulator reads the temperatures measured by sensors TC and TR and compares the resulting temperature difference with the switching-on difference which is preset to 6 K. The regulator tries to achieve a temperature difference of 20 K (factory setting) between the collector and the tank to produce high temperature hot water as rapidly as possible.
  • Page 54 5. Commissioning 200SE-2S - 300SE-2S n Minimum collector temperature - CMIN The minimum collector temperature function CMIN prevents the solar pump from starting up too frequently in the event of low temperatures in the solar collector. The minimum collector temperature CMIN must be exceeded in order for the solar heating pump to be able to start M002765-A n Collector antifreeze option - OAC...
  • Page 55 200SE-2S - 300SE-2S 5. Commissioning n Pump command mode - POMP The POMP parameter is used to select the correct command program for the solar pump, according to the type of pump used. PSOL control (default setting) is designed for PWM solar-controlled heating pumps, PuLS control for conventional frequency-modulation heating pumps and OnOF control for "ON/OFF heating pumps.
  • Page 56 5. Commissioning 200SE-2S - 300SE-2S Installer parameter O td User setting Auto 3-position switch E Back-up at night Activated between tn O and tn F until Off Activated between tn O and tn F until THRn THRn Back-up during the day Off Off Installer parameter O td On or OFF...
  • Page 57 200SE-2S - 300SE-2S 5. Commissioning n Antifreeze type - GELT The GELT parameter is used to set the type of antifreeze used. The antifreeze concentration value is preset for using Tyfocor LS / G-LS and Greenway products. If using another antifreeze, select the setting values 1 or 2 and then set the GEL% parameter.
  • Page 58: Checking And Maintenance

    6. Checking and maintenance 200SE-2S - 300SE-2S Checking and maintenance General instructions CAUTION Maintenance operations must be done by a qualified engineer. Only original spare parts must be used. Safety valve or safety unit The safety valve or unit on the domestic cold water inlet must be operated at least once a month to ensure proper operating and to prevent from any overpressure which may that may damage the domestic hot water calorifier.
  • Page 59: Descaling

    200SE-2S - 300SE-2S 6. Checking and maintenance Descaling In regions with hard water, annual descaling of the appliance is recommended in order to maintain its performance. 1. Remove the inspection hatches. ¼ See chapter: "Removing the inspection hatches", page 2. Check the magnesium anode each time the hatch is opened. ¼...
  • Page 60: Remounting The Inspection Hatches

    6. Checking and maintenance 200SE-2S - 300SE-2S 6.6.2. Remounting the inspection hatches 1. Replace the lip seal and position it in the visit opening, making sure that you place its lug outside the DHW tank. L000389-C 2. Replace the sheet gasket. 3.
  • Page 61: Inspection And Maintenance Of The Solar Circuit

    200SE-2S - 300SE-2S 6. Checking and maintenance Inspection and maintenance of the solar circuit 6.7.1. Maintenance operations to be performed WARNING Use only the same fluid as for refilling. Do not mix different fluids. 1. Check the level of the heat transporting fluid. Top up the solar fluid if necessary.
  • Page 62: Maintenance Form

    6. Checking and maintenance 200SE-2S - 300SE-2S Maintenance form Maintenance N°: ......... Owner ......................Company name ..................Street ......................Street......................Town/Postcode..................... Town/Postcode .................... Tel..........Fax............Tel..........Fax............Mobile ......................Mobile ......................E-mail......................E-mail ......................Installer ......................Description of the installation Solar installation for: Hot water preparation Additional heating...
  • Page 63 200SE-2S - 300SE-2S 6. Checking and maintenance Installation controlled in integrality Installation in perfect condition Installation faults ............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................Place: ......................Date:....................
  • Page 64: Installation Report

    6. Checking and maintenance 200SE-2S - 300SE-2S Installation report Place of installation ................ Company name ................Owner .................... Street..................... Street ..................... Town/Postcode ................Town/Postcode................Tel..........Fax......... Tel..........Fax.......... Mobile.................... Mobile .................... E-mail .................... E-mail..................... Installer..................Description of the installation Solar installation for: Hot water preparation Additional heating...
  • Page 65 200SE-2S - 300SE-2S 6. Checking and maintenance Inspection of the installation Components on roof: All mounting bolts tight All connections checked and leak-free Solar station: Outlet and return connections correct Outlet and return thermometers present and checked Tank: Cold water safety kit installed Pressure reducer set at ....
  • Page 66: Troubleshooting

    7. Troubleshooting 200SE-2S - 300SE-2S Troubleshooting Electricity supply DANGER Before any work, switch off the mains supply to the control system. If the LED or the display are off, check the mains supply to the control system. The regulator is protected by a 4 A fuse. 1.
  • Page 67: Incidents And Solutions

    200SE-2S - 300SE-2S 7. Troubleshooting Incidents and solutions Description Checks Solutions The indicator light is off. The fuse is defect. Replace the fuse. ¼See chapter: "Electricity supply", page 64. The current has been cut. Restore the current. The solar pump is running but the DHW calorifier Air bubbles are present in the Vent the heating installation.
  • Page 68: Spare Parts

    8. Spare parts 200SE-2S - 300SE-2S Spare parts General When it is observed subsequent to inspection or maintenance work that a component in the appliance needs to be replaced, use only original spare parts or recommended spare parts and equipment. Always ensure that your return package is accompanied by the completed return form, see attached example.
  • Page 69: Spare Parts

    200SE-2S - 300SE-2S 8. Spare parts Spare parts 8.2.1. Domestic hot water tanks C004575-B 26/04/2016 - 7607575-05...
  • Page 70 8. Spare parts 200SE-2S - 300SE-2S Markers Reference Description 200SE-2S 300SE-2S 97860646 Adjustable foot M10 x 35 200022499 Plug 3/4" 300026994 Insulation, buffer tank 300026735 Side cover 300026876 Side insulation 200021489 Domestic hot water thermostatic mixing valve 200021501 Inspection trap screws 300026031 EPDM seal 89705511 7 mm gasket + 5 mm retainer ring...
  • Page 71: Solar Station

    200SE-2S - 300SE-2S 8. Spare parts 8.2.2. Solar station n Overview C004576-B Markers Reference Description 300027858 Medium cover 7626021 Sol AEL regulator 300027856 Control system support AEL 300027874 Insulated copper pipe - Top 300027873 Insulated copper pipe - Left 300027872 Insulated copper pipe - Right 300028300 Copper pipe - Expansion vessel connection 300027870 18-litre expansion vessel 300027869 Expansion vessel bracket...
  • Page 72 8. Spare parts 200SE-2S - 300SE-2S Markers Reference Description 95013060 Green seal 24x17x2 97310700 Grease for O-ring 300027855 Control system support Ai 300027862 Red metal thermometer 300027938 Blue metal thermometer n Detailed drawing L000576-C Markers Reference Description 300028533 Back insulation module 300002992 Washer Ø...
  • Page 73: Electric Heating Resistance For 200/400) Only

    200SE-2S - 300SE-2S 8. Spare parts Markers Reference Description 300028535 Wall console 300028536 Screw M8x25 300028538 Cone union body retaining bush 300026341 Valve 3/4" FF Fixed valve pin 300019551 Locating pin 300004141 Bleeder valve stopper 3/8" 300028537 Degasser 3/4" 300028539 cone union body Ø 18.2x9 mm 300028540 Cone union body nut Ø...
  • Page 74 Appendix Information on the ecodesign and energy labelling directives...
  • Page 75 Contents Contents Specific information ................. . 3 Recommendations .
  • Page 76 1 Specific information Specific information Recommendations Note Only qualified persons are authorised to assemble, install and maintain the installation. Ecodesign Directive This product conforms to the requirements of European Directive 2009/125/EC on the ecodesign of energy-related products. Technical data - Hot water storage tank Tab.1 Technical parameters for hot water storage tank 200SE-2S...
  • Page 77 1 Specific information 7607575 - ErP02 - 21042016...
  • Page 80 © Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing. 26/04/2016 7607575-001-05...

This manual is also suitable for:

Remasol300se-2s

Table of Contents