S1
R1
Reference Terminals Description
1-2
S1
3-4
S2
5-6
S3
7
PWM
8
PWM
9-10
VBus
11-14
4
15
R1
16
N
17
N
18
R2-N
19
R2-L
20
L
26/04/2016 - 7607575-05
Solar sensor probe - TC
DHW sensor, lower tank zone - TR
DHW sensor - Electrical back-up - THR PT1000 FR
PWM solar circulation pump
PWM solar circulation pump
DL2 connection
Earthing terminals
Solar circulation pump
Solar circulation pump
230 V main supply
Electric heating resistance
Electric heating resistance
230 V main supply
Diagram with solar circuit and electrical back-up:
S3
S2
Connector / Sensor
PT1000 FK
PT1000 FR
-
+
Conductor - Green/Yellow
Live - Brown - (Cable provided)
Neutral - Blue - (Cable provided)
Neutral
Neutral
Live
Live
4. Installation
100 .. . 240 V~
L000452-C