Settings; Description Of The User Level Parameters; Description Of The Installer Level Parameters - REMEHA Quinta Ace Installation, User And Service Manual

Table of Contents

Advertisement

9

Settings

9.1

Description of the user level parameters

Tab.25
Factory settings
Parameter
Text display
AP016
Enable or disable central heating heatdemand
processing
AP017
Enable or disable domestic hot water heatdemand
processing
AP081
Shortname of the device
CP080
User Room Setpoint Zone Activity temperature
CP081
User Room Setpoint Zone Activity temperature
CP082
User Room Setpoint Zone Activity temperature
CP083
User Room Setpoint Zone Activity temperature
CP084
User Room Setpoint Zone Activity temperature
CP085
User Room Setpoint Zone Activity temperature
CP320
Operating mode of the zone
CP550
Fire Place mode is active
CP570
Time Program of the zone selected by the user
CP660
Choice icon to display this zone
9.2

Description of the installer level parameters

Tab.26
Factory settings
Parameter
Text display
AP001
Blocking input setting (1: Full blocking, 2: Partial
blocking, 3: User reset locking)
7625116 - v.04 - 17012017
Adjustment range
0 = Off
1 = On
0 = Off
1 = On
5 °C - 30 °C
5 °C - 30 °C
5 °C - 30 °C
5 °C - 30 °C
5 °C - 30 °C
5 °C - 30 °C
0 = Scheduling
1 = Manual
2 = Antifrost
3 = Temporary
0 = Off
1 = On
0 = Schedule 1
1 = Schedule 2
2 = Schedule 3
3 = Cooling
0 = None
1 = All
2 = Bedroom
3 = Livingroom
4 = Study
5 = Outdoor
6 = Kitchen
7 = Basement
Adjustment range
1 = Full blocking
2 = Partial blocking
3 = User reset locking
4 = Backup Relieved
5 = Heat Pump Relieved
6 = Heat Pump And backup Relieved
7 = High Tariff Low Tariff
8 = Photovoltaic Heat Pump Only
9 = Photovoltaic Heat Pump And backup
10 = Smart Grid ready
11 = Heating Cooling
9 Settings
160
1
1
CU6
16
20
6
21
22
20
1
0
0
1
160
1
45