Connecting The Solar Control System; Electrical Diagram - REMEHA RemaSol200SE-2S Installation And Service Manual

Solar hot water calorifer
Table of Contents

Advertisement

4. Installation
2
5
34
4 The instructions on the circuit diagrams provided with the
appliance,
4 The manufacturer's instructions.
Belgium: The earthing must comply with the RGIE standard.
Germany: The earth connection shall comply with standard
VDE 0100.
France: The earth connection shall comply with standard
NFC 15-100.
Other countries: The earthing shall comply with local standards.
CAUTION
4
4
The appliance is delivered pre-wired.
The electricity supply is connected to the mains by connection cable
(~230 V, 50 Hz) and electrical plug.
The electrical plug must be accessible at all times.
4.10.2.
DANGER
Do not expose the appliance to strong magnetic fields.
Keep the electrical connection cable separate from the
sensor cables.
CAUTION
It must be possible for the regulator to be isolated from the
mains by a circuit breaker that provides at least a 3 mm
gap between all the poles or by a circuit breaker that
conforms to installation standards.
1. Remove the insulating shell from the front of the solar station, if
necessary.
2. Remove the Phillips-head screws from the cover and detach it
from the box.
3. Make the electrical connection.
See electrical schematics.
4. Put the cover back in place and secure with the screws.
5. Put the insulating shell back in place if necessary.
M002758-A
4.10.3.
Separate the sensor cables from the 230/400 V
circuit cables.
The installation must be fitted with a main switch.

Connecting the solar control system

Electrical diagram

200SE-2S - 300SE-2S
26/04/2016 - 7607575-05

Advertisement

Table of Contents
loading

This manual is also suitable for:

Remasol300se-2s

Table of Contents