6.3.13 ISSUE COMMAND

Function
Issues labels according to the print conditions programmed.
Format
[ESC] XS; I, aaaa, bbbcdefgh [LF] [NUL]
Term
aaaa:
bbb:
c:
d:
e:
f:

Number of labels to be issued

0001 to 9999
Cut interval. Designates the number of pieces to be printed before the
backing paper is cut.
000 to 100 (no cut when 000)
Type of sensor
0: No sensor
1: Reflective sensor
2: Transmissive sensor (when using normal labels)
3: Transmissive sensor (when using normal labels)
4: Reflective sensor

Issue mode

C: Batch mode
D: Strip mode (with back feed, the strip sensor is valid. For 203dpi, 2ips
and 3ips are valid for strip mode, for 300dpi, 2ips is valid for
strip mode)
E: Strip mode (with back feed, the strip sensor is ignored,
the applicator supports this mode. For 203dpi, 2ips and 3ips
are valid for strip mode, for 300dpi, 2ips is valid for strip
mode.)
F: Partial cut mode (Non back feed cut mode)

Issue speed

1: 2 inches/sec
2: 2 inches/sec
3: 3 inches/sec
4: 4 inches/sec
5: 5 inches/sec (300dpi 4inches/sec)
6: 5 inches/sec (300dpi 4inches/sec)
7: 5 inches/sec (300dpi 4inches/sec)
8: 5 inches/sec (300dpi 4inches/sec)
9: 5 inches/sec (300dpi 4inches/sec)
A: Max. 2 inches/sec. or 5 inches/sec. (Depending on a duplicate printing
area setting for duplicate labels. Only for the 203 dpi model)
B: Max. 5 inches/sec. (When using duplicate labels and no duplicate printing
is necessary. Only for the 203 dpi model)
With/without ribbon
Direct thermal models:
Set to 0. (If "1" or "2" is specified, a ribbon error results.)
Thermal transfer models:
0:
Without ribbon
1:
With ribbon
2:
With ribbon
- 118 -