Electrical system
WARNING
ONLY IN EXTREMELY UNUSUAL AND SPECIFIC SITUATIONS CAN THE LAMBDA PROBE OP-
ERATION AFFECT VEHICLE PERFORMANCE.
Coil
Primary coil resistance 3.4 - 4.6 Ohm at 20 °C (68
°F) (between red/black cable and orange cable).
Secondary coil resistance 10.4 - 15.6 kOhm at 20
°C (68 °F) (between red/black cable and spark
plug cable).
Spark plug tube resistance 10.0 kOhm at 20 °C
(68°F).
Bank angle sensor
Voltage to be detected (between yellow/green ca-
ble and black/blue cable) Less than 65° tilting 0.4
- 1.4 V Over 65° inclination 3.7 - 4.4 V
NOTE
SENSOR FUNCTIONING CAN ALSO BE DETECTED
THROUGH THE INSTRUMENT PANEL.
SAS valve actuator
Resistance of the Secondary air system solenoid
18 - 22 Ohm at 20 °C (68 °F) (between brown/red
cable and red/white cable)
ELE SYS - 64
PEGASO 650 STRADA - TRAIL - FACTORY