Electrical system
Error code: DSB 03
Immobilizer failure: Internal controller failure
Error code: DSB 04
Fuel sensor failure
Error code: DSB 05
The instrument panel must keep all previous errors stored in its memory. In case of fuel sensor failure,
the relative icon on the display should flash.
Delete errors
This option deletes all the errors, both control unit and instrument panel errors; a further confirmation
is requested.
Reset service
This function is used to reset the service interval.
Disconnection
For collection data on Pegaso models, the instrument panel uses the K line for communicating with the
diagnosis instruments. To avoid any interference, the instrument panel should be in a status at which
no interference is possible, by the user's interface setting. Through the external devices, the control unit
will be reset and be also able to start interfacing with the diagnosis instrument.
The LCD shows:
Instrument panel disconnected. Now connect the diagnosis instrument.
The instrument panel will restart to work normally after the key is inserted-extracted.
Update
This function is used to program the instrument panel again. This screen shows the software version
that is currently loaded. The LCD shows:
Instrument panel disconnected. Now connect the diagnosis instrument.
The instrument panel will restart to work normally after the key is inserted-extracted.
Modify Keys
With this function the instrument can update the keys. Up to 4 keys can be stored.
The user code is first requested to be entered:
Enter the code.
After entering the correct code, the following message should be shown on the display:
Enter the X key.
X+1 programmed.
At least one key must be stored, for the next start-ups. If no other keys are inserted within 20 seconds
or if there is lack of power or after the fourth key is programmed, the procedure finishes and all the
functions of the vehicle and the instrument panel must be enabled (even if only one key has been
programmed).