Appendix A: Reference Data
November 2012
Ground Screw
Standard
(12)
V5
External Ground Screw Assembly
Drinking Water Approval
Standard
DW
NSF drinking water approval
Surface Finish
Standard
Q16
Surface finish certification for sanitary remote seals
Toolkit Total System Performance Reports
Standard
QZ
Remote Seal System Performance Calculation Report
Conduit Electrical Connector
Standard
GE
M12, 4-pin, Male Connector (eurofast
GM
A size Mini, 4-pin, Male Connector (minifast
Typical Model Number: 3051CD 2 A 2 2 A 1 A B4$13857 780
(1) 3051CG lower range limit varies with atmospheric pressure.
(2) 3051CD0 is available only with Output Code A, Process Flange Code 0 (Alternate Flange H2, H7, HJ, or HK), Isolating Diaphragm Code 2, O-ring Code A, and Bolting
Option L4.
(3) Option code M4 - LCD Display with Local Operator Interface required for local addressing and configuration.
(4) Not available with hazardous locations certification Options Codes I1, N1, E4, K6 and K8.
(5) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to
certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(6) "Assemble-to" items are specified separately and require a completed model number.
(7) Not available with Low Power code M.
(8) Available only with output code W - Profibus PA.
(9) Not available with Fieldbus (output code F) or Profibus (output code W).
(10) Local zero and span adjustments are standard unless Option Code J1 or J3 is specified.
(11) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
(12) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
Model
3051T
Pressure Transmitter
Pressure Type
Standard
G
Gage
A
Absolute
138
®
)
®
)
Transmitter Type
Reference Manual
00809-0100-4001, Rev JA
Standard
Standard
Standard
Standard
Standard
Standard
Specifications and reference data