Monitoring
Table 39:
Power Supply Environment—CLI
Power Supply-1
-------------------------------------------------------------------------
Status
Blower (1) Status : Operational
Speed Setting : 1 (2243 RPM)
Blower (2) Status : Operational
Speed Setting : 1 (2236 RPM)
Temperature
-------------------------------------------------------------------------
Figure 85. Sample: Show Power Supply Display
Supercapacitor Detailed
The ISE-2, Hyper ISE, and ISE 7-Series contain two supercapacitor units (see Figure 1 on page 4) to maintain
cache memory in the event of a power outage.
To view detailed information about the supercapacitor units and their environment, enter the show battery
command in the CLI. The following information is displayed for each supercapacitor unit (see Figure 86 for a
sample display from one supercapacitor unit).
Entering the show battery command in the CLI returns the same information as entering show
Note.
supercap.
The supercapacitor information fields are described in the following table (Table 40):
Field
Status
Detailed Status
Serial Number, Model, Part
Number
Hardware Version
Position
Temperature
Table 40:
Supercapacitor Environment Display
Figure 86. Sample: Show Battery Display
Xiotech—Proprietary
: Operational (None)
: 31 C (Warning: 50 C, Critical: 60 C)
Comment
Overall state of the SuperCap unit. This field usually reports Operational. Other possible
states include Warning, Critical, or Non-Operational.
Any unusual state this SuperCap unit may be in. This field usually reports None.
Component serial number, model, and part number
Physical bay location in the chassis, see Figure 101 on page 140
Current temperature of supercapacitor unit
160337-000 Rev D, 30 September, 2013
Position
: 1
Serial Number : RG29395
Part Number
: SP632-2P
ISE User Guide
Page 119