X-IO ISE-2 Series User Manual page 126

Ise storage blade
Table of Contents

Advertisement

ISE User Guide
Firmware Version
Temperature
--------------------------------------------------------------------------
======================================================================
Table 38:
Sample: Show DataPac Console Print
Field
Status
Detailed Status
Redundancy Health
Serial Number
Model
Part Number
Firmware Version
Type
Capacity
Position
Pool Identifier
Temperature
Power Supply Detailed
Enter the show powersupply or show ps command in the CLI. The following information (Table 39) is
displayed for each power supply and a sample display for a single power supply is shown in Figure 85.
Field
Status
Detailed Status
Serial Number
Model
Part Number
Blower Status, Speed
Position
Temperature
Page 118
: 100 (4202)
: 31 C (Warning: 50 C, Critical: 60 C)
Comment
Overall DataPac state, normal is Operational and other possible states: Warning, Criti-
cal, and Non-Operational
Normally None. Abnormal states are detailed here
Functional, relative DataPac storage remaining
DataPac serial number
Model number of DataPac
DataPac part number
DataPac firmware version
DataPac classification as Performance, Balanced, or Capacity
DataPac capacity stated in total Gigabytes (GB)
Physical bay location in the chassis; see Figure 101 on page 140
Values appearing in parenthesis after the DataPac number and are
DataPac temperature plus warning and critical temperature thresholds (see "Tempera-
ture Indicators" on page 116 for display details and SNMP trap information)
Comment
Overall power supply state, normally Operational, other possible states: Warning, Critical,
and Non-Operational
Shown in parentheses after Status; normal is None, abnormal states are detailed here
Serial number of the power supply
Model of the power supply
Part number of the power supply
Each power supply contains two blowers, all of which operate independently under sys-
tem control. Speeds are grouped into ten RPM ranges, from 1 (slowest) to 10 (fastest).
Physical bay location in the chassis; see Figure 101 on page 140
DataPac temperature plus warning and critical temperature thresholds (see "Temperature
Indicators" on page 116 for display details and SNMP trap information)
160337-000 Rev D, 30 September, 2013
Cache Generation: 1
0
Monitoring
or
1
Xiotech—Proprietary

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ise-3 seriesIse 7 seriesHyper ise

Table of Contents