Irf Split; Symptom; Troubleshooting Flowchart; Solution - HPE FlexNetwork 10500 SERIES Troubleshooting Manual

Table of Contents

Advertisement

The next system working mode is advance.
b. If the system operating mode of the chassis is different than the IRF fabric, execute
the system-working-mode command to change the system operating mode for the
chassis. The changed mode will take effect after a reboot.
11. Verify that the chassis has the same maximum number of ECMP routes as the IRF fabric:
a. Execute the display max-ecmp-num command and check the Max-ECMP-Num at the
next reboot field.
[Sysname] display max-ecmp-num
Max-ECMP-Num in use: 17
Max-ECMP-Num at the next reboot: 17
b. If the maximum number of ECMP routes of the chassis is different than the IRF fabric,
execute the max-ecmp-num command to change the number for the chassis. The changed
number will take effect after a reboot.
12. If the problem persists, contact Hewlett Packard Enterprise Support.

IRF split

Symptom

An IRF fabric splits.

Troubleshooting flowchart

Figure 21 Troubleshooting IRF split
IRF physical interfaces down?
Member chassis or module
that has IRF links rebooted?
Contact the support

Solution

To resolve the problem:
1.
Verify that the IRF physical interfaces are operating correctly:
a. Execute the display trapbuffer command or view system logs to check for physical IRF link
down events that occurred around the split time.
b. If the split followed an IRF link down event, execute the display interface command to
check port statistics for CRC errors.
IRF fabric
splits
Yes
No
Yes
No
Identify the cause and
resolve the problem
Identify the cause and
resolve the problem
60
Yes
Resolved?
No
Yes
Resolved?
No
End