❸ Use

3.1 I Operati ng principle

Your heat pump uses the calories (heat) in the air to heat up your pool's water. The process to heat your pool's water to
the temperature you want may take a few days as it depends on the weather conditi ons, your heat pump's power and
the diff erence between the water temperature and the temperature you want.
The heat pump is ideal for maintaining temperature.
The warmer and damper the air, the bett er your heat pump will perform. The outdoor parameters for opti mum operati on
are an air temperature of 27°C, a water temperature of 27°C and 80% hygrometry.
Tips: improve your pool's temperature rise and maintenance
Anti cipate the commissioning of your pool far enough in advance before you use it.
For the temperature rise, set the fi ltrati on pump to conti nuous operati on (24/24).
To maintain the temperature throughout the season, run "automati c" circulati on for at least 12 hours/
day (the longer this ti me the longer the heat pump will have enough operati ng range to heat up).
Cover the basin with a sheet (bubble canopy, canvas, etc.) to prevent heat loss.
Take advantage of a period with mild outdoor temperatures (on average > 10°C at night); your heat pump
will be even more eff ecti ve if it runs during the warmest hours of the day.
Keep the evaporator clean (see § "4.2 I Maintenance").
Set the temperature you want and let the heat pump run (adjusti ng the setpoint to maximum will not
heat the water more quickly).
Connect the "Heati ng priority"; the fi ltrati on pump and heat pump operati ng ti me will be set according
to requirements.

3.2 User interface presentati on

Display screen (default: setpoint temperature)
"On/off " butt on
Pool water temperature reading or parameter setti ng butt on
Value setti ng butt ons
Symbol
Designati on
Water fl ow
Heati ng
Ambient air
temperature
Priority heati ng
connected
Fault
H0548500.A - EN - 2015-11
Fixed
Water fl ow ok
Acti ve
Suffi cient
Priority heati ng connected and
heati ng request
Fault in progress, see § "5.2 I
Error code display"
Flashing
Water fl ow too low or missing
starti ng
Insuffi cient
Priority heati ng connected but no
heati ng request
Heati ng priority connected,
heati ng requested but water fl ow
too low or missing
EN
Off
/
Inacti ve
/
Priority heati ng
not connected
No fault