3.3 I Operati ng

Check that there are no tools or other foreign objects in the machine.
The panel that provides access to the technical secti on must be put in place.
Set the valves as follows: valve B wide open, valves A, C, D and E closed
• An incorrect by-pass setti ng may cause the heat pump to malfuncti on.
Check that the hydraulic correcti ons are correctly ti ghtened and that there are no leaks.
Check that the device is fully stable.
Set the water circulati on running.
Close valve B gradually so that the fi lter pressure is increased by 150g (0.150 bars).
Open valves A, C and D fully then valve E by half (the air which has built up in the heat pump condenser and the
fi ltrati on circuit will bleed out). If valves D and E are not present, open valve A wide and close valve C by half.
Connect the power supply to the heat pump:
Press and hold
for 2 seconds
Device starts aft er a ti mer of up to 5 minutes,
Set the temperature you want ("setpoint" temperature) by pressing
Aft er the steps to start up your heat pump, stop the water circulati on temporarily to check that your device stops aft er
a few seconds (by acti vati ng the fl ow controller):
9
: water entry valve
: by-pass valve
: water exit valve
: water entry adjustment valve (opti onal)
: water exit adjustment valve (opti onal)
program version number (diff erent according to model)
Screen saver
Splash screen
Temperature setpoint
or
.
the water fl ow light must fl ash.
H0548500.A - EN - 2015-11