I Electricity Supply Connecti Ons - Zodiac Z200 M2 Installation And Use Instructions Manual

Table of Contents

Advertisement

2.3 I Electricity supply connecti ons

Incorrectly ti ghtened terminals may cause the terminal unit to heat up and invalidate the
warranty.
• Before any work inside the device, you must cut the electricity supply as there is a risk of
electric shock which may cause material damage, serious injury or even death.
Only a qualifi ed and experienced technician is authorised to carry out cabling in the equipment
or to replace the supply cable.
The heat pump's electrical supply must be provided through a protecti on and circuit breaking device (not supplied)
complying with the standards and regulati ons in force in the country where it is installed,
The device is provided for connecti on to a general power supply with a TT and TN.S neutral regime.
Electrical protecti on: by circuit breaker (D curve) (for calibre, see § "1.2 I Technical specifi cati ons"), with a 30 mA
dedicated diff erenti al circuit breaker (circuit breaker or switch) at the head of the line.
The electricity supply must correspond to the voltage indicated on the device's informati on plate.
The electricity supply cable must be insulated against any cutti ng or hot elements that may damage or crush it.
The equipment must be connected to an earth socket.
The electrical connecti on lines must be fi xed.
Use the gland to pass the supply cable into the device.
Used the supply cable (RO2V type) adapted for outdoor or buried use (or run the cable into a protecti on duct).
We recommend burying the cable at a depth of 50 cl (85 cm under a road or path) in an electrical duct (red ribbed).
If this buried cable meets another cable or pipe (gas, water, etc.), there must be more than 20 cm between them.
Depending on the model, there are 2 ways to connect:
Device equipped with a cable with plug (depending on model)
Check that the supply cable is fi rmly att ached to the connecti on terminal.
All use of an extension cord or multi socket connecti on is prohibited.
If the supply cable is not long enough, contact a qualifi ed technician.
Connect the supply cable delivered with the appliance to a 16A socket, according to the
country's applicable standards and regulati ons.
Device not equipped with a cable (depending on model)
Connect the supply cable to the connecti on terminal unit inside the heat pump.
H0548500.A - EN - 2015-11
L: live
N: neutral
PE: earth
EN
6