❶ Installation; I Selecting The Location - Zodiac PX50 MD12 Instructions For Installation And Use Manual

Table of Contents

Advertisement

❶ Installation

1.1 I Selecting the location

• When the appliance is installed and protected by a residual current device (RCD) with a
maximum amperage of 30 mA, it should be installed at a distance of at least 2 metres from the
edge of the pool.
• If no RCD is installed with the appliance, it should be installed at a distance of at least 3.5
metres from the edge of the pool.
• Do not lift the appliance by the body; use its base.
• Installation is only permitted outdoors: provide for a clear space around the appliance as shown in the diagram under
§ "1.2 I Hydraulic connections".
• Place the appliance on its anti-vibration pads (supplied with the appliance, height adjustable) on a stable, solid and
level surface,
• This surface must be able to bear the weight (see § "5.2 I Technical specifications") of the appliance (in particular in
the case of installation on a roof, a balcony or any other support).
View of the appliance base from below for installing the anti-vibration pads
The appliance must not be installed:
• With the blowing towards any permanent or temporary obstacle less than 4 metres away,
• Within range of watering nozzles, sprays or water or mud run-off (take the effect of the wind into account),
• Near a heat source or flammable gas,
• Near high-frequency equipment,
• In a location where it would be subject to snow build-up,
• In a location where it might be flooded by the condensates produced by the appliance when operating.
Tip: to reduce noise produced by your heat pump
• Do not install it under or facing a window.
• Do not tilt it towards your neighbours.
• Install it in an open space (sound waves are reflected on surfaces).
• Install an acoustic screen around the heat pump, respecting the distances (see drawing § "1.2 I
Hydraulic connections").
• Install 50 cm of flexible PVC pipe at the heat pump water inlet and outlet to absorb vibrations.
: Front
: Rear
: Anti-vibration pads
EN
11

Advertisement