❹ Maintenance; I Wintering; I Maintenance - Zodiac Z200 M2 Installation And Use Instructions Manual

Table of Contents

Advertisement

4.1 I Wintering

• Wintering is vital to prevent the condenser breaking due to freezing. This is not covered by
the warranty.
• To avoid damaging the equipment with condensati on, do not fully cover it.
Switch off the device by pressing and holding
Close the water input and output valves and make sure that there is no water circulati ng in the heat pump,
Drain the water from the condenser (risk of freezing) by unscrewing the water input and output connectors on the
back of the heat pump,
In the case of full wintering for the pool (complete shutdown of the fi ltrati on system, bleed the fi ltrati on circuit or
even pool drainage): ti ghten the two connectors by one turn to prevent any foreign bodies from getti ng into the
condenser,
In the case of wintering for the heat pump only (shutdown of the heati ng only, the fi ltrati on keeps running): to not
ti ghten the connectors but add 2 caps (provided) on the condenser's water inputs and outputs.
We recommend that you put the aired wintering micro cover on the heat pump.

4.2 I Maintenance

• It is recommended that the device be general serviced at least on a yearly basis to ensure
proper operati on, maintain performance levels and prevent some potenti al failures. These
operati ons are carried out at the user's expense, by a technician.
4.2.1 User maintenance
Make sure that the fi lter is not blocked by any foreign bodies.
Clean the evaporator (for locati on see § "1.3 I Dimensions and marking") using a soft brush and a fresh water spray
(disconnect the power cable); do not fold over the metal wings, then clean the condensati on drainage pipe to remove
any impuriti es that may be blocking it.
Do not use a high pressure jet. Do not spray with rain water, salt water or water which is full of minerals.
Clean the outside of the device; do not use any solvent-based products. We can provide you with a specifi c cleaning
kit as an accessory: the PAC NET, see § "1.1 I Descripti on".
4.2.2 Maintenance to be carried out by a qualifi ed technician
Check that the regulati on is operati ng correctly connected.
Check that the condensati on fl ows correctly when the device is operati ng.
Check the safety mechanisms.
Check the connecti on of the metal masses to the earth.
Check that the electrical cables are correctly ti ghtened and connected and that the electrical unit is clean.
11
❹ Maintenance
for 2 seconds and disconnect it or switch off the electricity supply,