❺ Troubleshooti ng
• Before you contact your reseller, please carry out these few simple checks using the following
tables if a problem occurs.
• If the problem conti nues contact your reseller.
•
: Acti ons reserved for a qualifi ed technician
5.1 I Device behaviour
•
On start-up, the device remains "paused" for 5 minutes before it starts operati ng.
•
When the setpoint temperature is reached, the heat pump stops heati ng: the water temperature
is higher than or equal to the setpoint temperature.
The device does
•
When the water fl ow rate is zero or is not enough, the heat pump stops: check that the water is
not start heati ng
circulati ng correctly in the heat pump and that the hydraulic connecti ons are correct.
straight away
•
The heat pump stops when the outdoor temperature falls below 7 °C.
•
It may be that the heat pump has detected an operati ng fault (see § "5.2 I Error code display").
•
If you have checked these points and the problem persists: contact your reseller.
•
Oft en called condensati on, this water is the moisture contained in the air which condenses
on contact with certain cold mechanisms in the heat pump, especially on the evaporator. The
more damp the air, the more condensati on your heat pump will produce (your device may
drain several litres of water per day). This water is retrieved by the base of the heat pump and
The device is
drained through a hole.
draining water
•
To check that the water is not coming from a leak in the pool circuit on the heat pump, shut
down the heat pump, wait a few minutes and run the fi ltrati on pump for the water to circulate
in the heat pump. If the water conti nues to fl ow through the condensati on drain, there is a
water leak in the heat pump; contact your reseller.
•
Your heat pump will soon switch to its defrost cycle to melt the ice.
The evaporator is
•
If your heat pump cannot manage to deice its evaporator, it will stop itself; this means that the
iced over
outdoor temperature is too low (below 7°C).
•
•
When the setpoint temperature is reached, the heat pump stops heati ng: the water temperature
is higher than or equal to the setpoint temperature.
The device is not
•
When the water fl ow rate is zero or is not enough, the heat pump stops: check that the water
working
is circulati ng correctly in the heat pump.
•
The heat pump stops when the outdoor temperature falls below 7 °C.
•
It may be that the heat pump has detected an operati ng fault (see § "5.2 I Error code display").
•
It may be that the heat pump has detected an operati ng fault (see § "5.2 I Error code display").
•
Check that the automati c fi lling valve is not stuck in open positi on; this will keep supplying cold
The device is
water into the pool and will prevent the temperature from rising.
working but
•
There is too much heat loss as the air is cool. Install a heat insulated cover on your pool.
the water
•
The heat pump is unable to capture enough calories as its evaporator is clogged with dirt. Clean
temperature does
it to restore its performances (see § "4.2 I Maintenance").
not increase
•
Check that the external environment is not hindering the heat pump (see § "❷ Installati on").
Check that the external environment is not hindering the heat pump (see § "❷ Installati on").
•
The venti lator is
running but the
•
If the outdoor temperature is low, the heat pump will perform defrost cycles.
compressor stops
•
The heat pump is unable to capture enough calories as its evaporator is clogged with dirt. Clean
from ti me to ti me
it to restore its performances (see § "4.2 I Maintenance").
with no error
message
•
The device trips
the right one (see § "1.2 I Technical specifi cati ons").
the circuit breaker
•
H0548500.A - EN - 2015-11
If there is no display, check the supply voltage and the F1 fuse.
Check that the heat pump is the right size for this pool and its environment.
Check that the circuit breaker is correctly dimensioned and that the cable secti on used is
The supply voltage is too low; contact your electricity supplier.
EN
12