7.
Remove retainer (2) with screws (4).
8.
Remove supply unit (3) with screws (1) from
retainer (2).
Installing supply unit
1.
Install retainer (2) on supply unit (3).
2.
Tighten screws (1) to specified torque using a torque wrench.
Name
Screw
3.
Install supply unit (3) with retainer (2) on SCR catalytic converter.
178 | Exhaust Gas Aftertreatment | MS150123/01E 2017-05
Size
Type
M8
Tightening torque
Lubricant
Value/Standard
17.5 Nm ±3.5 Nm